Literature DB >> 10431457

A high voltage, constant current stimulator for electrocutaneous stimulation through small electrodes.

C J Poletto1, C L Van Doren.   

Abstract

A high-voltage stimulator has been designed to allow transcutaneous stimulation of tactile fibers of the fingertip. The stimulator's output stage was based upon an improved Howland current pump topology, modified to allow high load impedances and small currents. The compliance voltage of approximately 800 V is achieved using commercially available high-voltage operational amplifiers. The output current accuracy is better than +/- 5% over the range of 1 to 25 mA for 30 microseconds or longer pulses. The rise time for square pulses is less than 1 microsecond. High-voltage, common-mode, latch-up power supply problems and solutions are discussed. The stimulator's input stage is optically coupled to the controlling computer and complies with applicable safety standards for use in a hospital environment. The design presented here is for monophasic stimulation only, but could be modified for biphasic stimulation.

Mesh:

Year:  1999        PMID: 10431457     DOI: 10.1109/10.775402

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  11 in total

1.  Influence of electrode impedance on threshold voltage for transcranial electrical stimulation in motor evoked potential monitoring.

Authors:  H L Journée; H E Polak; M de Kleuver
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

2.  Design and development of a low-cost biphasic charge-balanced functional electric stimulator and its clinical validation.

Authors:  Chandrashekhar Shendkar; Prasanna K Lenka; Abhishek Biswas; Ratnesh Kumar; Manjunatha Mahadevappa
Journal:  Healthc Technol Lett       Date:  2015-10-21

3.  Polarity effect in electrovibration for tactile display.

Authors:  Kurt A Kaczmarek; Krishnakant Nammi; Abhishek K Agarwal; Mitchell E Tyler; Steven J Haase; David J Beebe
Journal:  IEEE Trans Biomed Eng       Date:  2006-10       Impact factor: 4.538

4.  Electrodes for high-definition transcutaneous DC stimulation for applications in drug delivery and electrotherapy, including tDCS.

Authors:  Preet Minhas; Varun Bansal; Jinal Patel; Johnson S Ho; Julian Diaz; Abhishek Datta; Marom Bikson
Journal:  J Neurosci Methods       Date:  2010-05-19       Impact factor: 2.390

5.  A Portable, Arbitrary Waveform, Multichannel Constant Current Electrotactile Stimulator.

Authors:  Jesse Cornman; Aadeel Akhtar; Timothy Bretl
Journal:  Int IEEE EMBS Conf Neural Eng       Date:  2017-08-15

6.  neuroBi: A Highly Configurable Neurostimulator for a Retinal Prosthesis and Other Applications.

Authors:  Kyle D Slater; Nicholas C Sinclair; Timothy S Nelson; Peter J Blamey; Hugh J McDermott
Journal:  IEEE J Transl Eng Health Med       Date:  2015-07-13       Impact factor: 3.316

7.  The tongue display unit (TDU) for electrotactile spatiotemporal pattern presentation.

Authors:  K A Kaczmarek
Journal:  Sci Iran D Comput Sci Eng Electr Eng       Date:  2011-12

Review 8.  A dual mode pulsed electro-magnetic cell stimulator produces acceleration of myogenic differentiation.

Authors:  Walter D Leon-Salas; Hatem Rizk; Chenglin Mo; Noah Weisleder; Leticia Brotto; Eduardo Abreu; Marco Brotto
Journal:  Recent Pat Biotechnol       Date:  2013-04

9.  A high-voltage bipolar transconductance amplifier for electrotactile stimulation.

Authors:  Matthew A Schaning; Kurt A Kaczmarek
Journal:  IEEE Trans Biomed Eng       Date:  2008-10       Impact factor: 4.538

10.  Compact Current Reference Circuits with Low Temperature Drift and High Compliance Voltage.

Authors:  Sara Pettinato; Andrea Orsini; Stefano Salvatori
Journal:  Sensors (Basel)       Date:  2020-07-28       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.