Literature DB >> 10424983

Treatment plan for restoring the edentulous maxilla with implant-supported restorations: removable overdenture versus fixed partial denture design.

N U Zitzmann1, C P Marinello.   

Abstract

STATEMENT OF PROBLEM: Restoring the edentulous maxilla with a fixed complete denture or a removable overdenture is a complex and challenging procedure.
PURPOSE: This article presents and discusses the crucial factors involved in deciding whether a fixed or removable implant prosthesis should be planned in fulfilling the patient's preference for optimal esthetics, phonetics, comfort, and function. METHODS AND MATERIAL: A concept for treatment planning is presented that enables the practitioner to check the decisive parameters during the first examination and to make the final decision with the help of the reformatted computerized tomography scan.
CONCLUSION: If this treatment plan is followed, implants can be placed to comply with the selected prosthetic solution and compromised solutions can be avoided. The fixed design for implant prosthesis is only appropriate for patients with minimal resorption of the alveolar bone and an optimal maxillomandibular relationship. The removable overdenture may be indicated from the outset and is no longer restricted to patients with a compromised situation in which fixed implant prostheses are not feasible.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10424983     DOI: 10.1016/s0022-3913(99)70155-1

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Does professional experience save teeth? A survey among prosthodontists.

Authors:  Shaza Bishti; Julia Lautensack; Jens C Türp; Stefan Wolfart
Journal:  Clin Oral Investig       Date:  2017-07-20       Impact factor: 3.573

2.  CAD/CAM technologies in the surgical and prosthetic treatment of the edentulous patient with biomymetic individualized approach.

Authors:  A Pozzi; M Gargari; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

3.  Reliability and Time Efficiency of Digital vs. Analog Bite Registration Technique for the Manufacture of Full-Arch Fixed Implant Prostheses.

Authors:  Philippe Nuytens; Rani D'haese; Stefan Vandeweghe
Journal:  J Clin Med       Date:  2022-05-19       Impact factor: 4.964

4.  Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations.

Authors:  Pisut Thangwarawut; Pokpong Amornvit; Dinesh Rokaya; Sirichai Kiattavorncharoen
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

5.  Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage.

Authors:  Min-Jeong Kim; Sung-Ok Hong
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

6.  Success rate in implant-supported overdenture and implant-supported fixed denture in cleft lip and palate patients.

Authors:  Jaine Zanolla; Flávio Monteiro Amado; Willian Saranholi da Silva; Bruno Ayub; Ana Lúcia Pompéia Fraga de Almeida; Simone Soares
Journal:  Ann Maxillofac Surg       Date:  2016 Jul-Dec

7.  Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar.

Authors:  Sung-Ki Chae; Won-Tak Cho; Jae-Won Choi; Eun-Bin Bae; Ji-Hyeon Bae; Gang-Ho Bae; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

8.  Clinical Performance of Implant Crown Retained Removable Partial Dentures for Mandibular Edentulism-A Retrospective Study.

Authors:  Soo-Yeon Yoo; Seong-Kyun Kim; Seong-Joo Heo; Jai-Young Koak; Hye-Rin Jeon
Journal:  J Clin Med       Date:  2021-05-18       Impact factor: 4.241

9.  Alteration of Oral and Perioral Soft Tissue in Mice following Incisor Tooth Extraction.

Authors:  Takahiro Takagi; Masahito Yamamoto; Aki Sugano; Chiemi Kanehira; Kei Kitamura; Masateru Katayama; Katsuhiko Sakai; Masaki Sato; Shinichi Abe
Journal:  Int J Mol Sci       Date:  2022-03-10       Impact factor: 5.923

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.