Effect of protein lubrication on the wear properties of materials for prosthetic joints.

Y S Liao1, P D Benya, H A McKellop.   

Abstract

The effects of pre-dilution and other modifications of bovine serum lubricants on the wear properties of UHMW polyethylene acetabular cups were evaluated in a hip joint simulator. The wear rate increased, and a nonphysiological type of surface-pitting occurred, when the serum was pre-diluted to 40% or lower concentration. During the wear test, the equilibrium temperature and the precipitation of proteins were substantially greater with zirconia balls than with cobalt-chromium. Protein precipitation, a potential modulator of in vitro wear, was shown to be temperature, concentration, and time-dependent in water-bath tests, which indicated that ball-cup interface temperatures in the simulator must be above 60 degrees C, i.e., well above the bulk lubricant temperature, to account for wear test protein precipitation. Several modifications of serum that were, in part, intended to decrease the tendency for protein precipitation were found to markedly affect the wear properties of the two combinations of materials. In particular, modified serum, which lacked some of the higher molecular weight proteins, produced a much higher wear rate than a control serum with the same initial protein concentration. The results indicated directions for further research to clarify the lubricating properties of serum, and for developing a universal standard test lubricant. Copyright 1999 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10421688     DOI: 10.1002/(sici)1097-4636(1999)48:4<465::aid-jbm10>3.0.co;2-y

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  14 in total

1.  The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Edward Ebramzadeh; Harry McKellop
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E.

Authors:  Ebru Oral; Steven D Christensen; Arnaz S Malhi; Keith K Wannomae; Orhun K Muratoglu
Journal:  J Arthroplasty       Date:  2006-06       Impact factor: 4.757

3.  Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.

Authors:  Marcel E Roy; Leo A Whiteside; Mark E Magill; Brian J Katerberg
Journal:  Clin Orthop Relat Res       Date:  2011-02-11       Impact factor: 4.176

4.  Nanoscale adhesion, friction and wear studies of biomolecules on silane polymer-coated silica and alumina-based surfaces.

Authors:  Bharat Bhushan; Kwang Joo Kwak; Samit Gupta; Stephen C Lee
Journal:  J R Soc Interface       Date:  2008-11-04       Impact factor: 4.118

5.  Preliminary tribological evaluation of nanostructured diamond coatings against ultra-high molecular weight polyethylene.

Authors:  Michael R Hill; Shane A Catledge; Valeriy Konovalov; William C Clem; Shafiul A Chowdhury; Brandon S Etheridge; Andrei Stanishevsky; Jack E Lemons; Yogesh K Vohra; Alan W Eberhardt
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-04       Impact factor: 3.368

6.  How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  J Mater Sci Mater Med       Date:  2014-07-12       Impact factor: 3.896

7.  In vitro comparison of wear characteristics of PyroCarbon and metal on bone: Shoulder hemiarthroplasty.

Authors:  Jerome J Klawitter; Jason Patton; Robert More; Noel Peter; Evgeny Podnos; Mark Ross
Journal:  Shoulder Elbow       Date:  2018-09-11

8.  The fundamentals of biotribology and its application to spine arthroplasty.

Authors:  Megan L Harper; Andrew Dooris; Philippe E Paré
Journal:  SAS J       Date:  2009-12-01

9.  High-tech hip implant for wireless temperature measurements in vivo.

Authors:  Georg Bergmann; Friedmar Graichen; Jörn Dymke; Antonius Rohlmann; Georg N Duda; Philipp Damm
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

10.  Tribo-biological deposits on the articulating surfaces of metal-on-polyethylene total hip implants retrieved from patients.

Authors:  Zhiwei Cui; Yi-Xing Tian; Wen Yue; Lei Yang; Qunyang Li
Journal:  Sci Rep       Date:  2016-06-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.