An in vitro analysis of the output of salbutamol from different nebulizers.

P W Barry1, C O'Callaghan.   

Abstract

The objective of this study was to determine the particle size and mass output of salbutamol from different nebulizers used under simulated breathing conditions. Seven nebulizer/compressor combinations were assessed. Each nebulizer was charged with 5 mg salbutamol solution and connected to a breathing simulator operating at tidal volumes of 150 mL and 600 mL. Nebulizers were operated for 15 min. Salbutamol collected on the filters was measured by liquid chromatography. Aerosol particle size was determined separately by laser diffraction. The Pari LC Star nebulizer delivered the most salbutamol at both tidal volumes. The maximal output of the Medicaid Ventstream and Sidestream nebulizers was two-thirds that of the LC Star, and they delivered less salbutamol than the LC Star or LC Plus nebulizers. The Intersurgical Cirrus nebulizer delivered the least salbutamol at both tidal volumes, although there was only a small difference between the Cirrus and Ventstream or Sidestream nebulizers at 150 mL tidal volume. The LC Plus nebulizer produced larger particles, mass median diameter 5.3 microm, compared with 3.6-4.0 microm for the other nebulizers. In conclusion, there were large differences in the delivery of salbutamol between the nebulizers studied, even between nebulizers of apparently the same class, and this should be borne in mind by regulatory authorities, clinicians and researchers.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10414421     DOI: 10.1034/j.1399-3003.1999.13e37.x

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  6 in total

1.  Suitability of the upper airway models obtained from MRI studies in simulating drug lung deposition from inhalers.

Authors:  T Ehtezazi; K W Southern; D Allanson; I Jenkinson; C O'Callaghan
Journal:  Pharm Res       Date:  2005-01       Impact factor: 4.200

Review 2.  Mechanisms of pharmaceutical aerosol deposition in the respiratory tract.

Authors:  Yung Sung Cheng
Journal:  AAPS PharmSciTech       Date:  2014-02-22       Impact factor: 3.246

3.  Tolerability and pharmacokinetics of inhaled bimosiamose disodium in healthy males.

Authors:  Michael Meyer; Kai-Michael Beeh; Jutta Beier; Diana Beyer; Ewald Aydt; Rainer Zahlten; Bernd Jilma; Gerhard Wolff
Journal:  Br J Clin Pharmacol       Date:  2006-09-20       Impact factor: 4.335

4.  Dose-response to salbutamol via a novel palm sized nebuliser (Aerodose Inhaler), conventional nebuliser (Pari LC Plus) and metered dose inhaler (Ventolin Evohaler) in moderate to severe asthmatics.

Authors:  Brian J Lipworth; Erika J Sims; Karla Taylor; Wendy Cockburn; Robert Fishman
Journal:  Br J Clin Pharmacol       Date:  2005-01       Impact factor: 4.335

5.  Jet nebulization of prostaglandin E1 during neonatal mechanical ventilation: stability, emitted dose and aerosol particle size.

Authors:  Beena G Sood; Jennifer Peterson; Monica Malian; Robert Galli; Maria Geisor-Walter; Jon McKinnon; Jody Sharp; Krishna Rao Maddipati
Journal:  Pharmacol Res       Date:  2007-10-02       Impact factor: 7.658

6.  A Novel Aerosol Method for the Production of Hydrogel Particles.

Authors:  Diana Guzman-Villanueva; Hugh D C Smyth; Dea Herrera-Ruiz; Ibrahim M El-Sherbiny
Journal:  J Nanomater       Date:  2011       Impact factor: 2.986

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.