Use of magnetic resonance imaging for in vivo measurements of water content in human brain: method and normal values.

P P Fatouros1, A Marmarou.   

Abstract

OBJECT: The authors present a quantitative in vivo magnetic resonance (MR) imaging method and propose its use for the accurate assessment of brain water in humans.
METHODS: With this technique, a pure T1-weighted image of a selected brain slice in a patient is generated, and the image is subsequently converted to a pure water image by means of an equation derived from a tissue relaxation model. The image intensity in the resulting water map directly yields absolute measures of water expressed in grams of water per gram of tissue at a given anatomical location. The method has been validated previously in a series of phantom experiments and in an infusion model of brain edema in cats. In this report, the authors evaluate the method by using samples of tissue harvested from patients who underwent surgery for brain tumor removal and apply the technique to a series of normal volunteers, providing average regional brain water content (f(w)) values for a range of tissues. Application of the method in pathological conditions such as head trauma, tumor, and hydrocephalus allows quantification of regional or global increases in f(w) that result from edema.
CONCLUSIONS: It is now possible to obtain accurate brain water measurements with the anatomical resolution of MR imaging. This permits monitoring of the development and resolution of edema in a variety of clinical circumstances, thus enhancing understanding of the underlying pathophysiological processes.

Entities:  

Mesh:

Year:  1999        PMID: 10413163     DOI: 10.3171/jns.1999.90.1.0109

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  31 in total

1.  Short-term stability of T1 and T2 relaxation measures in multiple sclerosis normal appearing white matter.

Authors:  Alice L W Liang; Irene M Vavasour; Burkhard Mädler; Anthony L Traboulsee; Donna J Lang; David K B Li; Alex L MacKay; Cornelia Laule
Journal:  J Neurol       Date:  2011-11-26       Impact factor: 4.849

2.  Comprehensive processing, display and analysis for in vivo MR spectroscopic imaging.

Authors:  A A Maudsley; A Darkazanli; J R Alger; L O Hall; N Schuff; C Studholme; Y Yu; A Ebel; A Frew; D Goldgof; Y Gu; R Pagare; F Rousseau; K Sivasankaran; B J Soher; P Weber; K Young; X Zhu
Journal:  NMR Biomed       Date:  2006-06       Impact factor: 4.044

Review 3.  Magnetic resonance imaging of myelin.

Authors:  Cornelia Laule; Irene M Vavasour; Shannon H Kolind; David K B Li; Tony L Traboulsee; G R Wayne Moore; Alex L MacKay
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

4.  Physical principles for scalable neural recording.

Authors:  Adam H Marblestone; Bradley M Zamft; Yael G Maguire; Mikhail G Shapiro; Thaddeus R Cybulski; Joshua I Glaser; Dario Amodei; P Benjamin Stranges; Reza Kalhor; David A Dalrymple; Dongjin Seo; Elad Alon; Michel M Maharbiz; Jose M Carmena; Jan M Rabaey; Edward S Boyden; George M Church; Konrad P Kording
Journal:  Front Comput Neurosci       Date:  2013-10-21       Impact factor: 2.380

5.  Evaluating quantitative proton-density-mapping methods.

Authors:  Aviv Mezer; Ariel Rokem; Shai Berman; Trevor Hastie; Brian A Wandell
Journal:  Hum Brain Mapp       Date:  2016-06-06       Impact factor: 5.038

Review 6.  Review of treatment assessment using DCE-MRI in breast cancer radiation therapy.

Authors:  Chun-Hao Wang; Fang-Fang Yin; Janet Horton; Zheng Chang
Journal:  World J Methodol       Date:  2014-06-26

Review 7.  Modeling white matter microstructure.

Authors:  T Duval; N Stikov; J Cohen-Adad
Journal:  Funct Neurol       Date:  2016 Oct/Dec

8.  White matter intercompartmental water exchange rates determined from detailed modeling of the myelin sheath.

Authors:  Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2018-09-19       Impact factor: 4.668

9.  A new algebraic method for quantitative proton density mapping using multi-channel coil data.

Authors:  Dietmar Cordes; Zhengshi Yang; Xiaowei Zhuang; Karthik Sreenivasan; Virendra Mishra; Le H Hua
Journal:  Med Image Anal       Date:  2017-06-23       Impact factor: 8.545

10.  High resolution MRI anatomy of the cat brain at 3 Tesla.

Authors:  Heather L Gray-Edwards; Nouha Salibi; Eleanor M Josephson; Judith A Hudson; Nancy R Cox; Ashley N Randle; Victoria J McCurdy; Allison M Bradbury; Diane U Wilson; Ronald J Beyers; Thomas S Denney; Douglas R Martin
Journal:  J Neurosci Methods       Date:  2014-02-10       Impact factor: 2.390

View more