Automated peritoneal dialysis in Asia.

K N Lai1, S L Lui, D T Chan.   

Abstract

The socioeconomic statuses of Asian countries are diverse, and government reimbursement policies for renal replacement programs vary greatly from one country to another. Both factors affect not only the availability of treatment, but also the choice of dialysis modality. A close correlation is demonstrated between the dialysis treatment rate for end-stage renal disease (ESRD) and the gross domestic product (GDP) per capita income. A biphasic relationship with the GDP per capita income and the peritoneal dialysis (PD) utilization rate is observed, in that the countries with the highest and lowest treatment rates tend to have lower PD utilization rates, whereas countries with modest treatment rates tend to have higher PD utilization rates. In contrast, countries with high continuous ambulatory peritoneal dialysis (CAPD) utilization rates have the lowest automated peritoneal dialysis (APD) utilization rates. The low APD utilization rates are due to fact that, in most instances, patients themselves must purchase the APD machine, and the machines are relatively more expensive in Asian Pacific countries. Continuous cycling peritoneal dialysis (CCPD) is most frequently practiced. Generally, convenience for employment is the main indication for the utilization of APD. Other important indications are the convenience of treatment in young or elderly uremic patients. Contrary to the practice in CAPD treatment, detailed documentation of dialysis adequacy and nutritional status is not routinely done in patients undergoing APD treatment in most Asian Pacific countries. In conclusion, APD is an underdeveloped treatment modality in the renal replacement programs of Asian Pacific countries. The low utilization of APD is clearly influenced by non medical factors including government reimbursement policy and the cost of PD machines.

Entities:  

Mesh:

Year:  1999        PMID: 10406506

Source DB:  PubMed          Journal:  Perit Dial Int        ISSN: 0896-8608            Impact factor:   1.756


  1 in total

1.  Safety, Effectiveness, and Manipulability of Peritoneal Dialysis Machines Made in China: A Randomized, Crossover, Multicenter Clinical Study.

Authors:  Xue-Ying Cao; Ya-Ni He; Jian-Hui Zhou; Shi-Ren Sun; Li-Ning Miao; Wen Chen; Jing-Ai Fang; Ming Wang; Nian-Song Wang; Hong-Li Lin; Jian Liu; Zhao-Hui Ni; Wen-Hu Liu; Yu Na; Jiu-Yang Zhao; Zhi-Yong Guo; Hong-Guang Zheng; Wei Shi; Geng-Ru Jiang; Guang-Yan Cai; Xiang-Mei Chen
Journal:  Chin Med J (Engl)       Date:  2018-12-05       Impact factor: 2.628

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.