Literature DB >> 10406148

Ultrasound biomicroscopy. III. Accuracy and agreement of measurements.

S F Urbak1.   

Abstract

PURPOSE: To estimate the accuracy of measurements by the 50 MHz Humphrey Ultrasound Biomicroscope and evaluate the agreement of measurements by ultrasound biomicroscopy and optical pachometry.
METHODS: The accuracy was estimated by comparing measurements by ultrasound biomicroscopy with more exact mechanical methods. Forty-seven PMMA intraocular lenses and 52 distances between horizontal separated sutures were measured. The agreement between ultrasound biomicroscopy and optical pachometry was evaluated by comparing measurements of central cornea thickness and anterior chamber depth of 46 eyes.
RESULTS: The axial measurements by ultrasound biomicroscopy was on average 10 microm higher than the reference method (SEM 3 microm). The lateral measurements was without systematic difference from the reference method (SEM 5 microm). The mean central corneal thickness was considerably higher by optical pachometry, 557+/-5 microm (SEM), than by ultrasound biomicroscopy, 533+/-5 microm. Similarly for anterior chamber depth where mean measurements were 2955+/-66 microm and 2897+/-63 microm, respectively.
CONCLUSIONS: The axial and lateral accuracy of ultrasound biomicroscopic measurements was good. The agreement between measurements obtained by ultrasound biomicroscopy and optical pachometry was poor in this investigation. Several circumstances could be accountable for this.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10406148     DOI: 10.1034/j.1600-0420.1999.770309.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  9 in total

Review 1.  Anterior segment imaging: ultrasound biomicroscopy.

Authors:  Hiroshi Ishikawa; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

2.  Effects of corneal thickness on intraocular pressure measured with three different tonometers.

Authors:  Hiroki Murase; Akira Sawada; Kiyofumi Mochizuki; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2009-01-30       Impact factor: 2.447

3.  Quantitative ultrasound method to detect and monitor laser-induced cavitation bubbles.

Authors:  Andrei B Karpiouk; Salavat R Aglyamov; Frederic Bourgeois; Adela Ben-Yakar; Stanislav Y Emelianov
Journal:  J Biomed Opt       Date:  2008 May-Jun       Impact factor: 3.170

4.  The Effectiveness of Ultrasound Biomicroscopic and Anterior Segment Optical Coherence Tomography in the Assessment of Anterior Segment Tumors: Long-Term Follow-Up.

Authors:  Joanna Konopińska; Łukasz Lisowski; Ewa Wasiluk; Zofia Mariak; Iwona Obuchowska
Journal:  J Ophthalmol       Date:  2020-06-16       Impact factor: 1.909

5.  Keeping an eye on decellularized corneas: a review of methods, characterization and applications.

Authors:  Samantha L Wilson; Laura E Sidney; Siobhán E Dunphy; James B Rose; Andrew Hopkinson
Journal:  J Funct Biomater       Date:  2013-07-10

6.  Clinical Features of Iris Cysts in Long-Term Follow-Up.

Authors:  Joanna Konopińska; Łukasz Lisowski; Zofia Mariak; Iwona Obuchowska
Journal:  J Clin Med       Date:  2021-01-07       Impact factor: 4.241

7.  Comparison of central corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and the Artemis-2 VHF scanner in normal eyes.

Authors:  Haya M Al-Farhan; Wafa'a Majed Al-Otaibi
Journal:  Clin Ophthalmol       Date:  2012-07-06

8.  Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy.

Authors:  Haya Matuoq Al Farhan; Wafa'a Majed Al Otaibi; Hanouf Mohammed Al Razqan; Alanoud Abdullah Al Harqan
Journal:  BMC Ophthalmol       Date:  2013-11-25       Impact factor: 2.209

9.  Assessment of Anterior Segment Changes in Pseudophakic Eyes, Using Ultrasonic Biomicroscopic Imaging, after Pars Plana Vitrectomy with Silicone Oil or Gas Tamponade.

Authors:  Erkan Ünsal; Kadir Eltutar; Belma Karini; Osman Kızılay
Journal:  J Ophthalmol       Date:  2016-05-19       Impact factor: 1.909

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.