Literature DB >> 10405597

Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry.

W Tong1, A Link, J K Eng, J R Yates.   

Abstract

A method to directly identify proteins in complex mixtures by solid-phase microextraction (micro-SPE)/multistep elution/capillary electrophoresis (CE)/tandem mass spectrometry (MS/MS) is described. A sheathless liquid-metal junction interface is used to interface CE and electrospray ionization MS/MS. A subfemtomole detection limit is achieved for protein identification through database searching using MS/MS data. The SPE serves as a semiseparation dimension using an organic-phase step-elution gradient in combination with the second separation dimension for increased resolving power of complex peptide mixtures. This approach improves the concentration detection limit for CE and allows more proteins in complex mixtures to be identified. A 75-protein complex from yeast ribosome is analyzed using this method and 80-90% of the proteins in the complex can be identified by searching the database using the MS/MS data from a complete analysis. This multidimensional CE/MS/MS methodology provides an alternative to multidimensional liquid chromatography/MS/MS for direct identification of small amounts of protein in mixtures.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10405597     DOI: 10.1021/ac9901182

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  18 in total

Review 1.  Molecular biologist's guide to proteomics.

Authors:  Paul R Graves; Timothy A J Haystead
Journal:  Microbiol Mol Biol Rev       Date:  2002-03       Impact factor: 11.056

2.  Nanoflow LC/IMS-MS and LC/IMS-CID/MS of protein mixtures.

Authors:  Renã A Sowell; Stormy L Koeniger; Stephen J Valentine; Myeong Hee Moon; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2004-09       Impact factor: 3.109

3.  Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry as an alternative proteomics platform to ultraperformance liquid chromatography-electrospray ionization-tandem mass spectrometry for samples of intermediate complexity.

Authors:  Yihan Li; Matthew M Champion; Liangliang Sun; Patricia A DiGiuseppe Champion; Roza Wojcik; Norman J Dovichi
Journal:  Anal Chem       Date:  2012-01-09       Impact factor: 6.986

Review 4.  Recent trends of capillary electrophoresis-mass spectrometry in proteomics research.

Authors:  Fabio P Gomes; John R Yates
Journal:  Mass Spectrom Rev       Date:  2019-08-12       Impact factor: 10.946

5.  Bottom-up proteome analysis of E. coli using capillary zone electrophoresis-tandem mass spectrometry with an electrokinetic sheath-flow electrospray interface.

Authors:  Xiaojing Yan; David C Essaka; Liangliang Sun; Guijie Zhu; Norman J Dovichi
Journal:  Proteomics       Date:  2013-08-01       Impact factor: 3.984

6.  Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for quantitative parallel reaction monitoring of peptide abundance and single-shot proteomic analysis of a human cell line.

Authors:  Liangliang Sun; Guijie Zhu; Si Mou; Yimeng Zhao; Matthew M Champion; Norman J Dovichi
Journal:  J Chromatogr A       Date:  2014-07-17       Impact factor: 4.759

7.  Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis.

Authors:  Yueju Wang; Bryan R Fonslow; Catherine C L Wong; Aleksey Nakorchevsky; John R Yates
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

8.  Comparison of two-dimensional fractionation techniques for shotgun proteomics.

Authors:  James A Dowell; Dustin C Frost; Jiang Zhang; Lingjun Li
Journal:  Anal Chem       Date:  2008-08-05       Impact factor: 6.986

9.  Single-shot proteomics using capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry with production of more than 1250 Escherichia coli peptide identifications in a 50 min separation.

Authors:  Guijie Zhu; Liangliang Sun; Xiaojing Yan; Norman J Dovichi
Journal:  Anal Chem       Date:  2013-02-13       Impact factor: 6.986

10.  Capillary electrophoresis applied to proteomic analysis.

Authors:  Bryan R Fonslow; John R Yates
Journal:  J Sep Sci       Date:  2009-04       Impact factor: 3.645

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.