Literature DB >> 10404363

Comparison of contact lens overrefraction and standard keratometry for measuring corneal curvature in eyes with lenticular opacity.

W G Zeh1, D D Koch.   

Abstract

PURPOSE: To assess the accuracy of corneal power measurement by contact lens overrefraction in patients with normal corneas and to determine the suitability of this method for use in intraocular lens (IOL) calculations.
SETTING: General ophthalmology clinic at a public hospital (Ben Taub General Hospital, Houston, Texas, USA).
METHODS: Using contact lens overrefraction (CLO), and standard keratometry, the corneal power in 33 eyes of 20 normal patients and patients scheduled for cataract extraction was prospectively measured. The eyes were divided into 3 groups based on their best spectacle-corrected visual acuity: (1) 20/20 to 20/40, (2) 20/50 to 20/70, and (3) 20/80 to 20/400. For each group, the means (absolute and arithmetic), standard deviations, and ranges of differences in corneal power as measured by CLO and keratometry were calculated. These values were used to estimate the induced variance in refractive outcome for IOL calculations.
RESULTS: The mean absolute differences in corneal power by group were 0.35 diopter (D) +/- 0.18 (SD), 0.54 +/- 0.33 D, and 0.77 +/- 0.28 D, respectively. The mean arithmetic differences in corneal power were -0.05 +/- 0.39 D, +0.37 +/- 0.51 D, and +0.17 +/- 0.80 D, respectively.
CONCLUSIONS: In eyes of patients with good visual acuity (20/20 to 20/40), corneal power measurements by CLO and keratometry were similar. The accuracy of the CLO-derived value decreased with increasing media opacity but was still acceptable with acuity of 20/70. Contact lens overrefraction may be a viable alternative to refractive history and videokeratography for estimating true corneal power in patients with surgically altered or irregular corneas.

Entities:  

Mesh:

Year:  1999        PMID: 10404363     DOI: 10.1016/s0886-3350(99)00088-7

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  10 in total

1.  Comparison of intraocular lens power calculation methods in eyes that have undergone laser-assisted in-situ keratomileusis.

Authors:  Li Wang; Marc A Booth; Douglas D Koch
Journal:  Trans Am Ophthalmol Soc       Date:  2004

2.  Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).

Authors:  Henry Gelender
Journal:  Trans Am Ophthalmol Soc       Date:  2006

3.  Practical method to calculate post-LASIK corneal power: the Actual K(a+p) method.

Authors:  Yi-Qian Hu; Xiang-Yu Ye; Xiu-Li Zhou; Yin Li; Cheng-Hui Xu; Lin-Lu Tian; Huang Zhu; Yao-Hua Sheng
Journal:  Int J Ophthalmol       Date:  2010-12-18       Impact factor: 1.779

4.  Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography.

Authors:  Maolong Tang; Li Wang; Douglas D Koch; Yan Li; David Huang
Journal:  Saudi J Ophthalmol       Date:  2012-01

5.  An intraocular lens power calculation formula based on optical coherence tomography: a pilot study.

Authors:  Maolong Tang; Yan Li; David Huang
Journal:  J Refract Surg       Date:  2010-06-17       Impact factor: 3.573

6.  Intraocular lens power calculation after previous myopic laser vision correction based on corneal power measured by Fourier-domain optical coherence tomography.

Authors:  Maolong Tang; Li Wang; Douglas D Koch; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2012-04       Impact factor: 3.351

7.  Intraocular lens power calculation after corneal refractive surgery.

Authors:  Vahid Feiz
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

8.  The comparison of central and mean true-net power (Pentacam) in calculating IOL-power after refractive surgery.

Authors:  Jeong-Ho Yi; Joo Youn Shin; Byoung Jin Ha; Sang Woo Kim; Beom Jin Cho; Eung Kweon Kim; Tae-im Kim
Journal:  Korean J Ophthalmol       Date:  2009-03-09

Review 9.  Intraocular lens power calculation following laser refractive surgery.

Authors:  Christopher Hodge; Colm McAlinden; Michael Lawless; Colin Chan; Gerard Sutton; Aifric Martin
Journal:  Eye Vis (Lond)       Date:  2015-04-02

Review 10.  Intraocular lens power calculation in eyes with previous corneal refractive surgery.

Authors:  Giacomo Savini; Kenneth J Hoffer
Journal:  Eye Vis (Lond)       Date:  2018-07-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.