Literature DB >> 10399418

Reliability and validity of a new device to measure isometric strength in polyarticular exercises.

F Verdera1, L Champavier, C Schmidt, S Bermon, P Marconnet.   

Abstract

BACKGROUND: The purpose of this study was to assess the validity of a new device to evaluate isometric strength during multi-joint exercise such as the squat or bench press.
METHODS: The device used an electric motor-driven bar to simultaneously generate and measure forces during weight lifting exercises. This new device and a force platform measured the forces generated by either the motor on a fixed telescopic steel girder (passive condition) or a subject pushing vertically against the bar from three squat positions (active condition). In the passive condition, 252 measurements were made, with 3 trials for 6 bar heights and 14 bar loads. In the active condition, 8 young physically active students (age, height and body mass were 25.1 +/- 2.6 years, 179.3 +/- 7.2 cm and 82.0 +/- 9.9 kg, respectively) performed 3 maximal isometric strength (MIS) trials in each of the 3 squat exercise positions (parallel, half and quarter squat), and 3 additional MIS trials in one position randomly assigned two weeks later to test inter-day reliability.
RESULTS: In the passive condition, no differences were observed between the forces measured by the force platform and the new device. The coefficient of linear regression (r) and the coefficient of variation (CV) were 1 and below 0.23%, respectively. In the active condition, the peak MIS measured was 2828 N and the values of r and CV were above 0.982 and below 5.96%, respectively. The assessment of inter-day reliability showed an r value of 0.984 and a CV of 3.98%.
CONCLUSIONS: This study demonstrated that the new electric motor-driven exerciser provides valid and reliable data when used to generate forces and measure isometric strength throughout the load and motion ranges commonly used in squat exercise.

Mesh:

Year:  1999        PMID: 10399418

Source DB:  PubMed          Journal:  J Sports Med Phys Fitness        ISSN: 0022-4707            Impact factor:   1.637


  7 in total

1.  Electromyographic analysis on a windsurfing simulator.

Authors:  Philippe Campillo; Barbara Leszczynski; Cédric Marthe; Jean Michel Hespel
Journal:  J Sports Sci Med       Date:  2007-03-01       Impact factor: 2.988

2.  The Reliability of 1- and 3Rm Tests of Unilateral Strength in Trained and Untrained Men and Women.

Authors:  Kevin McCurdy; George A Langford; Adam L Cline; Micheal Doscher; Russ Hoff
Journal:  J Sports Sci Med       Date:  2004-09-01       Impact factor: 2.988

3.  Reliability and Validity of the Athletic Shoulder (ASH) Test Performed Using Portable Isometric-Based Strength Training Device.

Authors:  Aleksandra Królikowska; Anna Mika; Bartosz Plaskota; Maciej Daszkiewicz; Monika Kentel; Anna Kołcz; Maciej Kentel; Robert Prill; Dorota Diakowska; Paweł Reichert; Artur Stolarczyk; Łukasz Oleksy
Journal:  Biology (Basel)       Date:  2022-04-11

Review 4.  Injury risk factors, screening tests and preventative strategies: a systematic review of the evidence that underpins the perceptions and practices of 44 football (soccer) teams from various premier leagues.

Authors:  Alan McCall; Chris Carling; Michael Davison; Mathieu Nedelec; Franck Le Gall; Serge Berthoin; Gregory Dupont
Journal:  Br J Sports Med       Date:  2015-01-09       Impact factor: 13.800

5.  Avoiding Systematic Errors in Isometric Squat-Related Studies without Pre-Familiarization by Using Sufficient Numbers of Trials.

Authors:  Ekim Pekünlü; Ilbilge Ozsu
Journal:  J Hum Kinet       Date:  2014-10-10       Impact factor: 2.193

Review 6.  The Validity and Responsiveness of Isometric Lower Body Multi-Joint Tests of Muscular Strength: a Systematic Review.

Authors:  David Drake; Rodney Kennedy; Eric Wallace
Journal:  Sports Med Open       Date:  2017-06-19

7.  The Athletic Shoulder (ASH) test: reliability of a novel upper body isometric strength test in elite rugby players.

Authors:  Ben Ashworth; Patrick Hogben; Navraj Singh; Laura Tulloch; Daniel D Cohen
Journal:  BMJ Open Sport Exerc Med       Date:  2018-07-23