Literature DB >> 10398019

Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene.

D A Baker1, R S Hastings, L Pruitt.   

Abstract

The aim of this work is to understand the role of chemical and radiation induced crosslinking on the fatigue crack propagation resistance of medical grade ultrahigh molecular weight polyethylene (UHMWPE). In recent years, the need to improve the tribological performance of UHMWPE used in total joint replacements has resulted in the widespread utilization of crosslinking as a method to improve wear resistance. Although crosslinking has been shown to drastically improve the wear resistance of the polymer, the potential trade-off in fatigue properties has yet to be addressed. Fatigue crack propagation resistance is a concern in tibial inserts where large cyclic stresses are sufficient to drive the growth of subsurface cracks that potentially contribute to delamination wear mechanisms. For clinical relevance, the combined effects of sterilization and aging are examined in two commercially available crosslinked resins. Nonsterile and unaged resins serve as a control. To evaluate the effect of crosslinking, a comparison is made to uncrosslinked resins. Scanning electron microscopy is used to provide an understanding of fatigue fracture mechanisms in the crosslinked polymers. The results of this study show that the current level of crosslinking used in orthopedic resins for enhanced wear resistance is not beneficial for fatigue crack propagation resistance. Copyright 1999 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10398019     DOI: 10.1002/(sici)1097-4636(19990915)46:4<573::aid-jbm16>3.0.co;2-a

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  15 in total

1.  Biomechanical changes of the lumbar segment after total disc replacement : charite(r), prodisc(r) and maverick(r) using finite element model study.

Authors:  Ki-Tack Kim; Sang-Hun Lee; Kyung-Soo Suk; Jung-Hee Lee; Bi-O Jeong
Journal:  J Korean Neurosurg Soc       Date:  2010-06-30

2.  Early failure of a cross-linked polyethylene acetabular liner. A case report.

Authors:  K David Moore; Preston R Beck; Donald W Petersen; John M Cuckler; Jack E Lemons; Alan W Eberhardt
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

Review 3.  Hip replacement in the athlete: is there a role?

Authors:  M J Wilson; R N Villar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-12       Impact factor: 4.342

4.  Highly crosslinked polyethylene improves wear but not surface damage in retrieved acetabular liners.

Authors:  Hee-Nee Pang; Douglas D R Naudie; Richard W McCalden; Steven J MacDonald; Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

5.  Peak stress intensity factor governs crack propagation velocity in crosslinked ultrahigh-molecular-weight polyethylene.

Authors:  Abhiram Sirimamilla; Jevan Furmanski; Clare Rimnac
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-11-19       Impact factor: 3.368

6.  Crack initiation from a clinically relevant notch in a highly-crosslinked UHMWPE subjected to static and cyclic loading.

Authors:  Abhi Sirimamilla; Clare M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2018-12-28

Review 7.  Vitamin E-stabilized UHMWPE for total joint implants: a review.

Authors:  Pierangiola Bracco; Ebru Oral
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

Review 8.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

9.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

10.  Application of viscoelastic fracture model and non-uniform crack initiation at clinically relevant notches in crosslinked UHMWPE.

Authors:  P Abhiram Sirimamilla; Jevan Furmanski; Clare M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2012-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.