Literature DB >> 10397182

Polymetallism and osseointegration in oral implantology: pilot study on primate.

B Foti1, P Tavitian, A Tosello, J J Bonfil, J C Franquin.   

Abstract

In oral implantology, successful results in osseointegration are obtained in the medium term (6-12 months) with commercially pure titanium implants. However, current superstructures can be of a different nature (precious metal or titanium) and of different manufacture (cast or machine-produced). Polymetallism between the implant and the superstructure may lead to conditions of galvanic corrosion, and influence osseointegration. The study described establishes, on the one hand, the procedures of animal experimentation in primates and on the other, the techniques of analysis of histological sections. The first technique of analysis is based on histomorphometry and leads to the definition of an osseointegration index. The second technique of analysis consists of X spectrometry by dispersion of energy which enables a spectral analysis of selected points below the crestal neck of the implant (vulnerable area in the case of corrosive attack) to be obtained. It is noted that after 6months, two of which were of activation, osseointegration did not vary according to the nature of the superstructure (precious alloy or titanium). After 2 months, the presence of a precious alloy superstructure lead to titanium migration towards the area around the cervical region of the implant (10-50 microm). This phenomenon did not occur with a titanium implant. It can therefore be presumed that polymetallism leads to detectable corrosion after 2 months but without apparent modification of osseointegration.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10397182     DOI: 10.1046/j.1365-2842.1999.00404.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  5 in total

1.  Electrochemical Behaviour and Galvanic Effects of Titanium Implants Coupled to Metallic Suprastructures in Artificial Saliva.

Authors:  Ana Mellado-Valero; Anna Igual Muñoz; Virginia Guiñón Pina; Ma Fernanda Sola-Ruiz
Journal:  Materials (Basel)       Date:  2018-01-22       Impact factor: 3.623

2.  Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

Authors:  Susanne Merk; Christina Wagner; Veronika Stock; Marlis Eichberger; Patrick R Schmidlin; Malgorzata Roos; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-11-08       Impact factor: 3.623

Review 3.  Electrogalvanism in Oral Implantology: A Systematic Review.

Authors:  Meriem Amine; Wiam Merdma; Khalid El Boussiri
Journal:  Int J Dent       Date:  2022-08-05

4.  Oral factors affecting titanium elution and corrosion: an in vitro study using simulated body fluid.

Authors:  Hideki Suito; Yuki Iwawaki; Takaharu Goto; Yoritoki Tomotake; Tetsuo Ichikawa
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

Review 5.  Reversal of Osseointegration as a Novel Perspective for the Removal of Failed Dental Implants: A Review of Five Patented Methods.

Authors:  Rolf G Winnen; Kristian Kniha; Ali Modabber; Faruk Al-Sibai; Andreas Braun; Reinhold Kneer; Frank Hölzle
Journal:  Materials (Basel)       Date:  2021-12-17       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.