Literature DB >> 10394388

Initial experience of using an active beam delivery technique at PSI.

E Pedroni1, T Böhringer, A Coray, E Egger, M Grossmann, S Lin, A Lomax, G Goitein, W Roser, B Schaffner.   

Abstract

At PSI a new proton therapy facility has been assembled and commissioned. The major features of the facility are the spot scanning technique and the very compact gantry. The operation of the facility was started in 1997 and the feasibility of the spot scanning technique has been demonstrated in practice with patient treatments. In this report we discuss the usual initial difficulties encountered in the commissioning of a new technology, the very positive preliminary experience with the system and the optimistic expectations for the future. The long range goal of this project is to parallel the recent developments regarding inverse planning for photons with a similar advanced technology optimized for a proton beam.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10394388     DOI: 10.1007/bf03038879

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  2 in total

1.  Beam optics design of compact gantry for proton therapy.

Authors:  E Pedroni; H Enge
Journal:  Med Biol Eng Comput       Date:  1995-05       Impact factor: 2.602

2.  The 200-MeV proton therapy project at the Paul Scherrer Institute: conceptual design and practical realization.

Authors:  E Pedroni; R Bacher; H Blattmann; T Böhringer; A Coray; A Lomax; S Lin; G Munkel; S Scheib; U Schneider
Journal:  Med Phys       Date:  1995-01       Impact factor: 4.071

  2 in total
  4 in total

Review 1.  Proton therapy - Present and future.

Authors:  Radhe Mohan; David Grosshans
Journal:  Adv Drug Deliv Rev       Date:  2016-12-03       Impact factor: 15.470

2.  A Review of Proton Therapy - Current Status and Future Directions.

Authors:  Radhe Mohan
Journal:  Precis Radiat Oncol       Date:  2022-04-27

3.  The energy margin strategy for reducing dose variation due to setup uncertainty in intensity modulated proton therapy (IMPT) delivered with distal edge tracking (DET).

Authors:  Miao Zhang; Ryan T Flynn; Xiaohu Mo; Thomas Rock Mackie
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

4.  Good long-term visual outcomes of parapapillary choroidal melanoma patients treated with proton therapy: a comparative study.

Authors:  Alessia Pica; Damien C Weber; Laureen Vallat; Ciara Bergin; Jan Hrbacek; Claude Schweizer; Leonidas Zografos; Ann Schalenbourg
Journal:  Int Ophthalmol       Date:  2020-09-25       Impact factor: 2.031

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.