Literature DB >> 10392872

Management of arterial puncture site after catheterization procedures: evaluating a suture-mediated closure device.

U Gerckens1, N Cattelaens, E G Lampe, E Grube.   

Abstract

To overcome the challenge associated with achievement in hemostasis after a catheterization procedure, a suture-based closure device was compared with manual compression in a 600-patient randomized trial. The major study end points included the incidence of vascular complications and the time to ambulation after the procedure. The study included diagnostic or interventional procedures. The suture-mediated closure was performed immediately after the procedure independent of the anticoagulation level, whereas manual compression was performed per hospital protocol with sheath removal relying on normalization of patient's anticoagulation status. A significant reduction in time to achieve hemostasis (7.8 +/- 4.8 vs 19.6 +/- 13.2 minutes, p <0001) and time to ambulation (4.5 +/- 6.5 vs 17.8 +/- 5 hours, p <0001) was associated with use of the suture-mediated closure device. The incidence of vascular complications was similar in the overall population (5.7% for suturing device vs 11.3% for compression) or in the interventional patient subset (8.4% for suturing device vs 9.6% for compression). There was a significant reduction in the incidence of vascular complications in the diagnostic procedure subset (4.4% for suturing device vs 12.1% for compression, p <0.05). Thus, the use of a suture-mediated closure device represents a safe alternative to manual compression. Hemostasis and ambulation can be achieved faster with the suturing device than with manual compression, with a potential reduction in access site complications.

Entities:  

Mesh:

Year:  1999        PMID: 10392872     DOI: 10.1016/s0002-9149(99)00174-5

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

1.  Final report of the European multi-center registry using the Duett vascular sealing device.

Authors:  S Silber; A J Tofte; T O Kjellevand; E Grube; G Gershony
Journal:  Herz       Date:  1999-12       Impact factor: 1.443

Review 2.  Efficacy and safety of the perclose closer s device after neurointerventional procedures: prospective study and literature review.

Authors:  Kamran Khaghany; Firas Al-Ali; Thomas Spigelmoyer; Ron Pimentel; Kurt Wharton
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

Review 3.  Anticoagulation During AF Ablation: The Balance between Thromboembolism and Bleeding.

Authors:  Jennifer A Mears; Samuel J Asirvatham
Journal:  J Atr Fibrillation       Date:  2009-02-01

4.  Short-Term Safety and Efficacy of Femoral Vascular Closure after Percutaneous Coronary Intervention with Combination of the Boomerang(TM) Device and Intravenous Protamine Sulfate.

Authors:  Ching-Pei Chen; Huang-Kai Huang; Chien-Hsun Hsia; Yung-Ming Chang; Lee-Shin Lin; Cheng-Liang Lee
Journal:  Acta Cardiol Sin       Date:  2013-11       Impact factor: 2.672

5.  Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade.

Authors:  Niels Zorger; Thomas Finkenzeller; Markus Lenhart; Okka Hamer; Christian Paetzel; Inghita Borisch; Ingolf Toepel; Stefan Feuerbach; Johann Link
Journal:  Eur Radiol       Date:  2003-11-11       Impact factor: 5.315

6.  Vascular closure device failure: frequency and implications: a propensity-matched analysis.

Authors:  Sripal Bangalore; Nipun Arora; Frederic S Resnic
Journal:  Circ Cardiovasc Interv       Date:  2009-10-27       Impact factor: 6.546

7.  Prospective comparison of collagen plug (Angio-Seal) and suture-mediated (the Closer S) closure devices at femoral access sites.

Authors:  Yulri Park; Hong Gee Roh; Sung Wook Choo; Sung Hoon Lee; Sung Wook Shin; Young Soo Do; Hong Sik Byun; Kwang Bo Park; Pyoung Jeon
Journal:  Korean J Radiol       Date:  2005 Oct-Dec       Impact factor: 3.500

8.  Long-term clinical outcomes after deployment of femoral vascular closure devices in coronary angiography and percutaneous coronary intervention: an observational single-centre registry follow-up.

Authors:  Stephen Wai-Luen Lee; Chor-Cheung Tam; Ka-Lam Wong; Shun-Ling Kong; See-Yue Yung; Yiu-Tung Wong; Suk-Yee Chiu; Cheung-Chi Lam; Ki-Wan Chan; Hon-Wah Chan
Journal:  BMJ Open       Date:  2014-06-12       Impact factor: 2.692

9.  Efficacy of femoral vascular closure devices in patients treated with anticoagulant, abciximab or thrombolytics during percutaneous endovascular procedures.

Authors:  Ha Young Kim; Sung Wook Choo; Hong Gee Roh; Heon Han; Sam Soo Kim; Ji Yeon Lee; Yul Ri Park; Sung Hoon Lee; Sung Wook Shin; Kwang Bo Park; Young Soo Do; Sung Ki Cho; In Ho Lee; Sung Mok Kim; Hong Sik Byun; Pyoung Jeon
Journal:  Korean J Radiol       Date:  2006 Jan-Mar       Impact factor: 3.500

Review 10.  Network Meta-analysis of Randomized Trials on the Safety of Vascular Closure Devices for Femoral Arterial Puncture Site Haemostasis.

Authors:  Jun Jiang; Junjie Zou; Hao Ma; Yuanyong Jiao; Hongyu Yang; Xiwei Zhang; Yi Miao
Journal:  Sci Rep       Date:  2015-09-08       Impact factor: 4.379

View more