Literature DB >> 10388886

Effect of the Palmaz balloon-expandable metallic stent in the trachea of pigs.

J L Ruegemer1, J A Perkins, K S Azarow, L K O'Bryant, R E Nielsen, R W Thomas.   

Abstract

Endoscopically placed airway stents offer a viable option in primary or adjunctive treatment of severe pediatric tracheobronchial stenoses. Optimistic clinical reports substantiate the need for experimental studies to more effectively evaluate their clinical role. Development of an animal model comparable with the pediatric airway, amenable to endoscopic instrumentation, and capable of assessing effect on growth was the purpose of this pilot project. Nine 4-week-old piglets underwent endoscopic midtracheal placement of the balloon-expandable Palmaz metallic stent. Initial expansion and stent position were verified fluoroscopically and by direct videobronchoscopy. Serial endoscopic examination and stent reexpansion were performed 2 and 4 weeks after stent insertion. Animal weight, clinical tolerance, tracheal growth, and stent integrity were observed. Tracheal inflammation was evaluated grossly and by objective histopathologic criteria. Successful endotracheal stent placement and expansion were accomplished in all piglets. One pig died of anesthesia complications less than 24 hours after stent insertion. The remaining pigs exhibited excellent clinical tolerance through experiment completion. No detrimental effect on growth was noted, and effective dilatation of the stented tracheal region was observed. Stent incorporation was evident with significant mucosal ingrowth. Inflammation in the form of nonobstructing granulation tissue was present, and no evidence of necrosis or cartilage invasion was evident. The piglet trachea appears to be an excellent model for evaluation of expandable metallic airway stents in management of congenital and acquired tracheobronchial stenoses.

Entities:  

Mesh:

Year:  1999        PMID: 10388886     DOI: 10.1016/S0194-5998(99)70132-4

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   3.497


  2 in total

1.  In-vivo efficacy of biodegradable ultrahigh ductility Mg-Li-Zn alloy tracheal stents for pediatric airway obstruction.

Authors:  Jingyao Wu; Leila J Mady; Abhijit Roy; Ali Mübin Aral; Boeun Lee; Feng Zheng; Toma Catalin; Youngjae Chun; William R Wagner; Ke Yang; Humberto E Trejo Bittar; David Chi; Prashant N Kumta
Journal:  Commun Biol       Date:  2020-12-18

2.  Comparison of three kinds of self-expandable metallic stents induced granulation tissue hyperplasia in the rabbit trachea.

Authors:  Yahua Li; Mengde Li; Xiaofeng Wang; Yuhui Wang; Chang Li; Yanan Zhao; Zhaonan Li; Jianjian Chen; Jing Li; Kewei Ren; Zongming Li; Jianzhuang Ren; Xinwei Han; Qian Li
Journal:  Sci Rep       Date:  2021-11-30       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.