Literature DB >> 10383090

In vitro image characteristics of an abdominal aortic stent graft: CTA versus 3D MRA.

P R Hilfiker1, H H Quick, M Schmidt, J F Debatin.   

Abstract

Percutaneous stent-grafting is increasingly employed as a less invasive alternative to surgery for the treatment of infrarenal abdominal aortic aneurysms. It requires long-term imaging follow-up, to document the structural integrity of the device, to exclude perigraft channels and endograft leakages, as well as the shrinkage of the aneurysmal sac. The expectation of severe stent induced artifacts and safety concerns have prevented 3D MRA from being used. The purpose of this in vitro study was to investigate the imaging characteristics of a bifurcated stent graft with 3D MRA (3D Fourier transform fast spoiled GRE) at 1.5 T in comparison to those of CTA. Measurement of the stent wall thickness and luminal diameter were made on a agar gel embedded stent graft at five locations on both CTA and MRA images. The stent graft was depicted as a dark ring on MR images. Wall thickness measurements at the five locations of the stent graft overestimated the true stent thickness, while luminal diameters were slightly underestimated. Measurement differences between MR and CT were not statistically significant (P = 0.67; P = 0.85). Artifacts emanating from the platinum markers were considerably less severe on the MR-images. A wider area of signal loss was seen only at the insertion of the iliac stent leg into the aortic stent portion due to the overlap of two radio-opaque platinum markers. 3D MRA images should permit a comprehensive assessment of the arterial lumen, and of perivascular tissues.

Entities:  

Mesh:

Year:  1999        PMID: 10383090     DOI: 10.1007/bf02590632

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  15 in total

1.  Utility of clinical pathway and prospective case management to achieve cost and hospital stay reduction for aortic aneurysm surgery at a tertiary care hospital.

Authors:  S C Muluk; L Painter; S Sile; R Y Rhee; M S Makaroun; D L Steed; M W Webster
Journal:  J Vasc Surg       Date:  1997-01       Impact factor: 4.268

2.  Long-term survival after elective repair of infrarenal abdominal aortic aneurysm: results of a prospective multicentric study. Association for Academic Research in Vascular Surgery (AURC).

Authors:  F Koskas; E Kieffer
Journal:  Ann Vasc Surg       Date:  1997-09       Impact factor: 1.466

Review 3.  Endovascular treatment of abdominal aortic aneurysms: lessons learned.

Authors:  J C Parodi; A Barone; R Piraino; C Schonholz
Journal:  J Endovasc Surg       Date:  1997-05

4.  Evaluation of ferromagnetism and magnetic resonance imaging artifacts of the Strecker tantalum vascular stent.

Authors:  G P Teitelbaum; M Raney; M J Carvlin; A H Matsumoto; K H Barth
Journal:  Cardiovasc Intervent Radiol       Date:  1989 May-Jun       Impact factor: 2.740

5.  Transfemoral, endovascular stented graft repair of an abdominal aortic aneurysm.

Authors:  J C Parodi; M L Marin; F J Veith
Journal:  Arch Surg       Date:  1995-05

6.  Clinical safety of gadopentetate dimeglumine.

Authors:  K L Nelson; L M Gifford; C Lauber-Huber; C A Gross; T A Lasser
Journal:  Radiology       Date:  1995-08       Impact factor: 11.105

7.  Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging.

Authors:  P F New; B R Rosen; T J Brady; F S Buonanno; J P Kistler; C T Burt; W S Hinshaw; J H Newhouse; G M Pohost; J M Taveras
Journal:  Radiology       Date:  1983-04       Impact factor: 11.105

8.  Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts.

Authors:  U Blum; M Langer; G Spillner; C Mialhe; F Beyersdorf; C Buitrago-Tellez; G Voshage; C Düber; V Schlosser; A H Cragg
Journal:  Radiology       Date:  1996-01       Impact factor: 11.105

Review 9.  Safety of gadolinium-DTPA: extended clinical experience.

Authors:  H P Niendorf; J Haustein; I Cornelius; A Alhassan; W Clauss
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

10.  Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up with helical CT.

Authors:  A Rozenblit; M L Marin; F J Veith; J Cynamon; S I Wahl; C W Bakal
Journal:  AJR Am J Roentgenol       Date:  1995-12       Impact factor: 3.959

View more
  2 in total

1.  Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

Authors:  Stefanie Weigel; Bernd Tombach; David Maintz; Stefan Klotz; Thomas Vestring; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

2.  MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study.

Authors:  Volker Rasche; Alexander Oberhuber; Stephan Trumpp; Axel Bornstedt; Karl-Heinz Orend; Nico Merkle; Wolfgang Rottbauer; Martin Hoffmann
Journal:  Eur Radiol       Date:  2011-02-18       Impact factor: 5.315

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.