Literature DB >> 10374976

An in vivo evaluation of the reproducibility of intima-media thickness measurements of the carotid artery segments using B-mode ultrasound.

A D Montauban van Swijndregt1, E E De Lange, E De Groot, R G Ackerstaff.   

Abstract

B-mode ultrasound may be used to measure the intima-media thickness (IMT) in subjects with a history of atherosclerosis. The variability between measurements depends on the subjective interpretation of ultrasonographers and readers. The two carotid arteries, subdivided in common (CCA), bulbus (BUL) and internal (ICA) of 10 men with proven coronary disease, were scanned twice by two ultrasonographers with a 1-week interval. The IMTs were measured off-line by two readers. The number of IMT measurements was 75 (94%) of 80 in the CCA, 61 (76%) of 80 in the BUL and 43 (54%) of 80 in the ICA segment. In the CCA segment, the agreement between readers (mean = 0.02 mm; limits: -0.26 to +0.3 mm) and between visits for each reader separately (reader 1: mean = 0.01 mm; limits: -0.33 to +0.35 mm and, reader 2: mean = 0.04 mm; limits: -0.36 to +0.44 mm) was better than in the more distal segments. Therefore, it is concluded that IMT measurements are best performed in the CCA segment.

Entities:  

Mesh:

Year:  1999        PMID: 10374976     DOI: 10.1016/s0301-5629(98)00183-5

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

1.  Hypercholesterolaemia is not associated with early atherosclerotic lesions in primary biliary cirrhosis.

Authors:  M Allocca; A Crosignani; A Gritti; G Ghilardi; D Gobatti; D Caruso; M Zuin; M Podda; P M Battezzati
Journal:  Gut       Date:  2006-04-21       Impact factor: 23.059

2.  Accelerated atherosclerosis in patients with Wegener's granulomatosis.

Authors:  K de Leeuw; J-S Sanders; C Stegeman; A Smit; C G Kallenberg; M Bijl
Journal:  Ann Rheum Dis       Date:  2004-09-16       Impact factor: 19.103

Review 3.  New advances in noninvasive imaging of the carotid artery: CIMT, contrast-enhanced ultrasound, and vasa vasorum.

Authors:  Blai Coll; Vijay Nambi; Steven B Feinstein
Journal:  Curr Cardiol Rep       Date:  2010-11       Impact factor: 2.931

Review 4.  Contrast enhanced ultrasound imaging.

Authors:  Steven B Feinstein; Blai Coll; Daniel Staub; Dan Adam; Arend F L Schinkel; Folkert J ten Cate; Kai Thomenius
Journal:  J Nucl Cardiol       Date:  2010 Jan-Feb       Impact factor: 5.952

5.  Improved imaging of the carotid artery in the short-axis plane by a mechanical scanning ultrasonic probe.

Authors:  Kazuki Kudo; Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2007-03-15       Impact factor: 1.314

6.  Carotid intima-media thickness in individuals with and without type 2 diabetes: a reproducibility study.

Authors:  Louise Lundby-Christensen; Thomas P Almdal; Bendix Carstensen; Lise Tarnow; Niels Wiinberg
Journal:  Cardiovasc Diabetol       Date:  2010-08-20       Impact factor: 9.951

7.  A practical protocol to measure common carotid artery intima-media thickness.

Authors:  Ivan Benaduce Casella; Calógero Presti; Rina Maria Pereira Porta; Cláudio Rogério Donmarco Sabbag; Maria Alice Bosch; Yumiko Yamazaki
Journal:  Clinics (Sao Paulo)       Date:  2008-08       Impact factor: 2.365

8.  Relation between serum uric acid and carotid intima-media thickness in healthy postmenopausal women.

Authors:  T Montalcini; G Gorgone; C Gazzaruso; G Sesti; F Perticone; A Pujia
Journal:  Intern Emerg Med       Date:  2007-03-31       Impact factor: 3.397

9.  The polymorphism rs6918289 located in the downstream region of the TREM2 gene is associated with TNF-α levels and IMT-F.

Authors:  Vesna Gorenjak; Alex-Ander Aldasoro Arguinano; Sébastien Dadé; Maria G Stathopoulou; Dwaine R Vance; Christine Masson; Sophie Visvikis-Siest
Journal:  Sci Rep       Date:  2018-05-08       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.