Literature DB >> 10370004

MR imaging: acronyms and clinical applications.

W R Nitz1.   

Abstract

The intention of this article is to provide an overview of all MR imaging techniques that are accessible on most of commercially available scanners and have the potential to be used in routine clinical applications. The techniques implemented by the major vendors are briefly explained, including a comparison of the commonly used acronyms. A classification scheme is introduced which provides a reasonable illustration of similarities and differences between various techniques. The imaging techniques are divided into two main groups, the spin-echo and gradient-echo sequences. Within each group is the basic sequence, those which require a preparation of the magnetization, those which use multiple echoes to fill the k-space and those which are performed in a single shot. For each technique the typical clinical applications are listed or the potential applications which have been published.

Mesh:

Year:  1999        PMID: 10370004     DOI: 10.1007/s003300050780

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  6 in total

Review 1.  [Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques].

Authors:  A M Wallnoefer; K A Herrmann; U Beuers; C J Zech; S Gourtsoyianni; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2005-11       Impact factor: 0.635

Review 2.  Appropriate selection of MRI sequences for common scenarios in clinical practice.

Authors:  Govind B Chavhan
Journal:  Pediatr Radiol       Date:  2016-05-26

Review 3.  Magnetic Resonanance Imaging of the Liver (Including Biliary Contrast Agents)-Part 2: Protocols for Liver Magnetic Resonanance Imaging and Characterization of Common Focal Liver Lesions.

Authors:  Andrea Agostini; Moritz F Kircher; Richard K G Do; Alessandra Borgheresi; Serena Monti; Andrea Giovagnoni; Lorenzo Mannelli
Journal:  Semin Roentgenol       Date:  2016-05-30       Impact factor: 0.800

4.  Obese patients in an open MRI at 1.0 Tesla: image quality, diagnostic impact and feasibility.

Authors:  Maximilian de Bucourt; Florian Streitparth; Uta Wonneberger; Jens Rump; Ulf Teichgräber
Journal:  Eur Radiol       Date:  2010-12-03       Impact factor: 5.315

5.  Quantification and Proximal-to-Distal Distribution Pattern of Tibial Nerve Lesions in Relapsing-Remitting Multiple Sclerosis : Assessment by MR Neurography.

Authors:  Adriana M Pietsch; Andrea Viehöver; Ricarda Diem; Markus Weiler; Mirjam Korporal-Kuhnke; Brigitte Wildemann; Georges Sam; John M Hayes; Olivia Fösleitner; Johann M E Jende; Sabine Heiland; Martin Bendszus; Jennifer C Hayes
Journal:  Clin Neuroradiol       Date:  2022-10-20       Impact factor: 3.156

6.  A Deep Convolutional Neural Network for Annotation of Magnetic Resonance Imaging Sequence Type.

Authors:  Sara Ranjbar; Kyle W Singleton; Pamela R Jackson; Cassandra R Rickertsen; Scott A Whitmire; Kamala R Clark-Swanson; J Ross Mitchell; Kristin R Swanson; Leland S Hu
Journal:  J Digit Imaging       Date:  2020-04       Impact factor: 4.056

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.