Literature DB >> 10367028

Development and evaluation of a phantom for morphometric X-ray absorptiometry.

S A Steel1, J A Thorpe, R Walker, S Howey, C M Langton.   

Abstract

Morphometric X-ray absorptiometry (MXA) provides the potential to assess vertebral deformity using a technique with much lower radiation dose to the patient than standard radiographic procedures. MXA overcomes many other limitations such as cone beam distortion observed in conventional plane radiographs. A phantom has been designed to assess the accuracy of the MXA technique, to monitor long-term precision and to assess inter- and intra-operator variability. The phantom consists of two columns of 12 cylinders representing the vertebral bodies, one of regular components and one representing vertebral deformities. Each column may be inserted, as required, into a Perspex torso-mimicking block. Initial assessment on the Lunar Expert-XL demonstrates that the phantom provides image parameters reflecting those found clinically. Measurement of vertebral height was found to be consistently underestimated by 4.9%. Operator precision ranged from 0.6% for posterior height measurement to 1.0% for middle height measurement of the regular component column. The corresponding precision range for the column representing vertebral deformation was 0.6% (posterior) and 1.1% (middle). Analysis of 10 scans of each column by two independent operators demonstrated a few significant differences in height assessment confined to the 'thoracic' region of the regular column. However, inter-operator variability was found to increase with increasing complexity of vertebral shape producing several differences, particularly in posterior height assessment of the deformed column.

Entities:  

Mesh:

Year:  1999        PMID: 10367028     DOI: 10.1007/s001980050114

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  2 in total

1.  New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis.

Authors:  Ciprian N Ionita; Brendan Loughran; Amit Jain; S N Swetadri Vasan; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-23

2.  Routine versus targeted vertebral fracture assessment for the detection of vertebral fractures.

Authors:  E T Middleton; S A Steel
Journal:  Osteoporos Int       Date:  2008-03-13       Impact factor: 4.507

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.