Literature DB >> 10360539

The impact of edema on planning 125I and 103Pd prostate implants.

N Yue1, A P Dicker, R Nath, F M Waterman.   

Abstract

Permanent transperineal interstitial 125I and 103Pd prostate implants are generally planned to deliver a specific dose to a clinically defined target volume; however, the post-implant evaluation usually reveals that the implant delivered a lower or higher dose than planned. This difference is generally attributed to such factors as source placement errors, overestimation of the prostate volume on CT, and post-implant edema. In the present work we investigate the impact of edema alone. In routine prostate implant planning, it is customary to assume that both the prostate and seeds are static throughout the entire treatment time, and post-implant edema is not taken into consideration in the dosimetry calculation. However, prostate becomes edematous after seed implantation, typically by 50% in volume [Int. J. Radiat. Oncol., Biol., Phys. 41, 1069-1077 (1998)]. The edema resolves itself exponentially with a typical half-life of 10 days. In this work, the impact of the edema-induced dynamic change in prostate volume and seed location on the dose coverage of the prostate is investigated. The total dose delivered to the prostate was calculated by use of a dynamic model, which takes edema into account. In the model, the edema resolves exponentially with time, as reported in a separate study based on serial CT scans [Int. J. Radiat. Oncol., Biol., Phys. 41, 1069-1077 (1998)]. The model assumes that the seeds were implanted exactly as planned, thus eliminating the effect of source placement errors. Implants based on the same transrectal ultrasound (TRUS) images were planned using both 125I and 103Pd sources separately. The preimplant volume and planned seed locations were expanded to different degrees of edema to simulate the postimplant edematous prostate on day 0. The model calculated the dose in increments of 24 h, appropriately adjusting the prostate volume, seed locations, and source strength prior to each time interval and compiled dose-volume histograms (DVH) of the total dose delivered. A total of 30 such DVHs were generated for each implant using different combinations of edema half-life and magnitude. In addition, a DVH of the plan was compiled in the conventional manner, assuming that the prostate volume and seeds were static during treatment. A comparison of the DVH of the static model to the 30 edema corrected DVHs revealed that the plan overestimated the total dose by an amount that increased with the magnitude of the edema and the edema half-life. The maximum overestimation was 15% for 125I and 32% for 103Pd. For more typical edema parameters (a 50% increase in volume and a 10 day half-life) the static plan for 125I overestimated the total dose by about 5%, whereas that for 103Pd overestimated it by about 12%.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10360539     DOI: 10.1118/1.598585

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Permanent prostate brachytherapy: the significance of postimplant dosimetry.

Authors:  W Robert Lee
Journal:  Rev Urol       Date:  2004

2.  Permanent prostate brachytherapy postimplant magnetic resonance imaging dosimetry using positive contrast magnetic resonance imaging markers.

Authors:  Geoffrey V Martin; Thomas J Pugh; Usama Mahmood; Rajat J Kudchadker; Jihong Wang; Teresa L Bruno; Tharakeswara Bathala; Pierre Blanchard; Steven J Frank
Journal:  Brachytherapy       Date:  2017-05-10       Impact factor: 2.362

3.  Is it necessary to perform week three dosimetric analysis in low-dose-rate brachytherapy for prostate cancer when day 0 dosimetry is done? A quality assurance assessment.

Authors:  T Shaikh; N G Zaorsky; K Ruth; D Y Chen; R E Greenberg; J Li; K Crawford; E M Horwitz
Journal:  Brachytherapy       Date:  2014-11-07       Impact factor: 2.362

4.  On the need to compensate for edema-induced dose reductions in preplanned (131)Cs prostate brachytherapy.

Authors:  Z Jay Chen; Jun Deng; Kenneth Roberts; Ravinder Nath
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-05       Impact factor: 7.038

5.  Quantification of edematic effects in prostate brachytherapy interventions.

Authors:  Mohamed Hefny; Purang Abolmaesumi; Zahra Karimaghaloo; David G Gobbi; Randy Ellis; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

6.  The impact of prostate volume changes during external-beam irradiation in consequence of HDR brachytherapy in prostate cancer treatment.

Authors:  Markus Karl Alfred Herrmann; Tammo Gsänger; Arne Strauss; Tereza Kertesz; Hendrik A Wolff; Hans Christiansen; Hilke Vorwerk; Clemens Friedrich Hess; Andrea Hille
Journal:  Strahlenther Onkol       Date:  2009-06-09       Impact factor: 3.621

Review 7.  Permanent interstitial brachytherapy for prostate cancer: a current review.

Authors:  Jeffrey Woolsey; Nicole Miller; Dan Theodorescu
Journal:  World J Urol       Date:  2003-08-13       Impact factor: 4.226

Review 8.  Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM.

Authors:  Christian Kirisits; Mark J Rivard; Dimos Baltas; Facundo Ballester; Marisol De Brabandere; Rob van der Laarse; Yury Niatsetski; Panagiotis Papagiannis; Taran Paulsen Hellebust; Jose Perez-Calatayud; Kari Tanderup; Jack L M Venselaar; Frank-André Siebert
Journal:  Radiother Oncol       Date:  2013-11-30       Impact factor: 6.280

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.