Literature DB >> 10360533

Dosimetric characteristics of a double-focused miniature multileaf collimator.

S L Meeks1, F J Bova, S Kim, W A Tomé, J M Buatti.   

Abstract

The dosimetric characteristics of a double-focused miniature multileaf collimator (mMLC) attached to a Philips SL75/5 linear accelerator (linac) have been investigated. Output factors, percentage depth-dose, penumbra, leaf transmission, and leakage between the leaves were measured for the 6 MV x-ray beam on this accelerator. Because leakage both through and between the leaves is minimal, the linac jaws can be kept fixed while the mMLC leaf configuration is modified for different aperture shapes. This allows for accurate output prediction using the equivalent square formalism. Percent depth-dose measured for fields defined by the mMLC show little deviation from the percent depth-dose measured for fields defined by the machine jaws or Lipowitz metal blocks. Because the mMLC matches beam divergence in both directions, allows minimal beam transmission, and has a large source-to-collimator distance, the penumbra is sharper for fields defined by the mMLC than for fields defined by the linac jaws or Lipowitz metal blocks. Based on these data, dose calculations for mMLC-defined fields can be applied with no change in procedures from those used for fields defined using conventional methods.

Mesh:

Year:  1999        PMID: 10360533     DOI: 10.1118/1.598579

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer.

Authors:  Youling Gong; Shichao Wang; Lin Zhou; Yongmei Liu; Yong Xu; You Lu; Sen Bai; Yuchuan Fu; Qingfeng Xu; Qingfeng Jiang
Journal:  Radiat Oncol       Date:  2010-07-15       Impact factor: 3.481

2.  Commissioning of a double-focused micro multileaf collimator (muMLC).

Authors:  Marcus Fischer; Manuel Todorovic; Eva Drud; Florian Cremers
Journal:  J Appl Clin Med Phys       Date:  2010-04-16       Impact factor: 2.102

3.  Stereotactic IMRT for prostate cancer: dosimetric impact of multileaf collimator leaf width in the treatment of prostate cancer with IMRT.

Authors:  L Wang; B Movsas; R Jacob; E Fourkal; L Chen; R Price; S Feigenberg; A Konski; A Pollack; C Ma
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

4.  Dosimetric characteristics of dual-layer multileaf collimation for small-field and intensity-modulated radiation therapy applications.

Authors:  Yaxi Liu; Chengyu Shi; Patricia Tynan; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2008-03-31       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.