Dispersion of filtered P wave duration by P wave signal-averaged ECG mapping system: its usefulness for determining efficacy of disopyramide on paroxysmal atrial fibrillation.

I Kubara1, H Ikeda, T Hiraki, T Yoshida, M Ohga, T Imaizumi.   

Abstract

INTRODUCTION: Although it is desirable to know drug efficacy before initiating antiarrhythmic therapy, there have been no methods for this evaluation. P wave signal-averaged ECG (P-SAECG) is useful to detect subtle changes in disturbance of atrial conduction. The purpose of this present study was to test whether P-SAECG mapping system would give any information on the efficacy of disopyramide on the prevention of paroxysmal atrial fibrillation (PAF). METHODS AND
RESULTS: P-SAECG was performed before disopyramide treatment, at 3 hours after a single dose of oral disopyramide (200 mg), and after 4 weeks of disopyramide treatment (300 mg/day). After measuring the filtered P wave duration by the vector magnitude and mapping methods, we calculated filtered P wave duration dispersion, difference between the maximal and minimal filtered P wave duration within 16 chest leads at these three time points. Filtered P wave duration and filtered P wave duration dispersion before treatment were longer in 32 patients with symptomatic PAF than in 31 healthy volunteers. Disopyramide was effective for suppression of PAF in 17 patients and ineffective in 15 patients after 4 weeks of treatment. Filtered P wave duration was similarly prolonged at 3 hours in the two groups, whereas filtered P wave duration dispersion at 3 hours after the disopyramide administration behaved differently; it decreased in all of the effective group and increased in all of the ineffective group. The effective patients were prospectively followed with the same treatment for 6 months. In 16 (94%) of these 17 effective patients, no PAF was documented and they remained to be asymptomatic.
CONCLUSIONS: Thus, measuring filtered P wave duration dispersion with the P-SAECG mapping method after a single administration may predict the long-term efficacy of disopyramide in patients with PAF.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10355923     DOI: 10.1111/j.1540-8167.1999.tb00244.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  7 in total

1.  Analysis of P wave and P dispersion in children with secundum atrial septal defect.

Authors:  T F Ho; E L Chia; W C Yip; K Y Chan
Journal:  Ann Noninvasive Electrocardiol       Date:  2001-10       Impact factor: 1.468

2.  Evaluation of bachmann bundle pacing versus right atrial pacing in prevention of atrial fibrillation after coronary artery bypass surgery.

Authors:  Chandrakant Chavan; Mukund Karmalkar; Rajesh Badani; K Sharada; Usha Rani; Prasad Rao; Ram Subramanyam; C Narasimhan
Journal:  Indian Pacing Electrophysiol J       Date:  2011-02-07

Review 3.  P-wave dispersion: a novel predictor of paroxysmal atrial fibrillation.

Authors:  P E Dilaveris; J E Gialafos
Journal:  Ann Noninvasive Electrocardiol       Date:  2001-04       Impact factor: 1.468

4.  The value of P dispersion on predicting atrial fibrillation after coronary artery bypass surgery: effect of magnesium on P dispersion.

Authors:  Sinan Dagdelen; Fevzi Toraman; Hasan Karabulut; Cem Alhan
Journal:  Ann Noninvasive Electrocardiol       Date:  2002-07       Impact factor: 1.468

5.  Automatic p wave analysis over 24 hours in patients with paroxysmal or persistent atrial fibrillation.

Authors:  Alexander Bitzen; Karsten Sternickel; Thorsten Lewalter; Jörg Otto Schwab; Alexander Yang; Jan Wilko Schrickel; Markus Linhart; Christian Wolpert; Werner Jung; Peter David; Berndt Lüderitz; Georg Nickenig; Lars Lickfett
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-10       Impact factor: 1.468

6.  Variable interatrial conduction illustrated in a hypertrophic cardiomyopathy population.

Authors:  Fredrik Holmqvist; Pyotr G Platonov; Jonas Carlson; Rasmus Havmöller; Johan E P Waktare; William J McKenna; S Bertil Olsson; Carl J Meurling
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-07       Impact factor: 1.468

7.  Role of biatrial pacing in prevention of atrial fibrillation after coronary artery bypass surgery.

Authors:  Massoud Eslami; Hamid S Mirkhani; Mehdi Sanatkar; Homeira Bayat; Roya Sattarzadeh; Mahmood Mirhoseini
Journal:  Indian Pacing Electrophysiol J       Date:  2005-01-01