Literature DB >> 10352588

Malignant pleural mesothelioma: US-guided histologic core-needle biopsy.

A Heilo1, A E Stenwig, O P Solheim.   

Abstract

PURPOSE: To assess the clinical use of ultrasonographically (US) guided core-needle biopsy, performed with a one-hand automatic sampling technique, in the diagnosis of malignant pleural mesothelioma (MPM).
MATERIALS AND METHODS: The authors reviewed the findings in 70 patients with a tentative diagnosis of MPM who underwent US-guided core-needle biopsy at our institution during the past 10 years.
RESULTS: Fifty-two of the 70 patients who underwent automatic high-speed core-needle biopsy at our institution had MPM; 18 had other disorders. The correct diagnosis was made in 56 patients. Twelve of 14 inadequate biopsy specimens were false-negative for MPM. There were no false-positive biopsy results. In the detection of MPM, US-guided core-needle biopsy had a sensitivity of 77%, specificity of 88%, accuracy of 80%, positive predictive value of 100%, and negative predictive value of 57%. There were no serious complications.
CONCLUSION: US-guided core-needle biopsy is highly effective in the diagnosis of MPM. Owing to its simplicity, low cost, and few side effects, it could be the biopsy method of choice for detection of this condition.

Entities:  

Mesh:

Year:  1999        PMID: 10352588     DOI: 10.1148/radiology.211.3.r99jn03657

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Image guided biopsy of the pleura: a useful diagnostic tool even when fluid is minimal.

Authors:  Mohan K Manu; Koteshwara Prakashini; Aswini Kumar Mohapatra; Ranjini Kudva
Journal:  BMJ Case Rep       Date:  2014-06-30

2.  Cytological Diagnostic Procedures in Malignant Mesothelioma.

Authors:  Christian Biancosino; Lea Isabell Shari van der Linde; Guido Sauter; Florian Stellmacher; Marcus Krüger; Lutz Welker
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

Review 3.  Diagnosis and management of malignant pleural effusions: state of the art in 2017.

Authors:  Neeraj R Desai; Hans J Lee
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

Review 4.  Pleural controversies: image guided biopsy vs. thoracoscopy for undiagnosed pleural effusions?

Authors:  Giles Dixon; Duneesha de Fonseka; Nick Maskell
Journal:  J Thorac Dis       Date:  2015-06       Impact factor: 2.895

5.  Ultrasound-guided pleural cutting needle biopsy: accuracy and factors influencing diagnostic yield.

Authors:  Yuxin Zhang; Jiaxin Tang; Xinghua Zhou; Dazhi Zhou; Jinlin Wang; Qing Tang
Journal:  J Thorac Dis       Date:  2018-06       Impact factor: 2.895

6.  CT-guided core needle biopsy of pleural lesions: evaluating diagnostic yield and associated complications.

Authors:  Xiang-Ke Niu; Anup Bhetuwal; Han-Feng Yang
Journal:  Korean J Radiol       Date:  2015-01-09       Impact factor: 3.500

7.  Diagnostic ability and its influenced factors of ultrasound-guided percutaneous pleural needle biopsy diagnosis for malignant pleural mesothelioma.

Authors:  Yuxin Zhang; Jiaxin Tang; Xinghua Zhou; Wuxi Chen; Shiyu Zhang; Yuqin Li; Dazhi Zhou; Liantu He; Qing Tang
Journal:  Front Surg       Date:  2022-09-26

8.  Tract metastasis from previously unknown malignant pleural mesothelioma: a case report.

Authors:  Tommaso Bartalena; Maria Francesca Rinaldi; Nicola Sverzellati; Vincenzo Allegri; Stefano Fanti
Journal:  Cases J       Date:  2009-06-29

9.  Accuracy of closed pleural biopsy in the diagnosis of malignant pleural effusion.

Authors:  Renata Báez-Saldaña; Uriel Rumbo-Nava; Araceli Escobar-Rojas; Patricia Castillo-González; Santiago León-Dueñas; Teresa Aguirre-Pérez; María Eugenia Vázquez-Manríquez
Journal:  J Bras Pneumol       Date:  2017 Nov-Dec       Impact factor: 2.624

  9 in total