Literature DB >> 30069320

Ultrasound-guided pleural cutting needle biopsy: accuracy and factors influencing diagnostic yield.

Yuxin Zhang1, Jiaxin Tang2, Xinghua Zhou1, Dazhi Zhou1, Jinlin Wang2, Qing Tang1.   

Abstract

BACKGROUND: The aim of this study was to retrospectively investigate the diagnostic accuracy of ultrasound-guided pleural cutting needle biopsy (US-guided PCNB) and the potential factors influencing diagnostic yield.
METHODS: From July 2014 to June 2016, a total of 147 percutaneous US-guided PCNBs in 144 patients were retrospectively reviewed. The final diagnosis was confirmed by histopathological analysis and follow-up. We calculated diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) and divided all cases into group of correct diagnoses (true-positive and true-negative cases) and group of incorrect diagnoses (false-positive, false-negative, and inconclusive cases). Univariate and multivariate logistic regression analyses were performed to analyze the differences of influencing factors (patient, pleura, and biopsy-associated factors) in the between the two groups.
RESULTS: Seven patients were excluded because of loss to follow-up. A total of 140 cases were ultimately included (105 males and 35 females). There were 105 cases in the correct diagnosis group, and 35 cases in the incorrect diagnosis group. The overall accuracy of US-PCNB was 75.0% and the sensitivity, specificity, PPV, NPV in malignant diagnosis were 58.1%, 99.0%, 96.2%, and 84.2%, respectively. On univariate analysis, variables affecting diagnostic accuracy of US-PCNB were the pleural thickness (<3 mm in thickness 61.0%, ≥3 mm in thickness 85.2%; P=0.001), morphology (non-nodular pleura 71.4%, nodular pleura 95.2%; P=0.026), and needle size (18 G 69.1%, 16 G 87.0%; P=0.022). Finally multivariate logistic regression demonstrated that pleural thickness [odds ratio (OR): 0.278, P=0.003] and needle size (OR: 0.291, P=0.018) independently predicted diagnostic accuracy.
CONCLUSIONS: Pleural thickness and the size of the biopsy needle were significantly correlated with the diagnostic yield.

Entities:  

Keywords:  Ultrasound-guided pleural biopsy; cutting needle; diagnostic accuracy; influencing factors; retrospective study

Year:  2018        PMID: 30069320      PMCID: PMC6051796          DOI: 10.21037/jtd.2018.05.94

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  30 in total

1.  Introduction and methods: British Thoracic Society Pleural Disease Guideline 2010.

Authors:  Ingrid Du Rand; Nick Maskell
Journal:  Thorax       Date:  2010-08       Impact factor: 9.139

Review 2.  [Diagnosis and treatment of pleural effusion].

Authors:  Victoria Villena Garrido; Jaime Ferrer Sancho; Luis Hernández Blasco; Alicia de Pablo Gafas; Esteban Pérez Rodríguez; Francisco Rodríguez Panadero; Santiago Romero Candeira; Angel Salvatierra Velázquez; Luis Valdés Cuadrado
Journal:  Arch Bronconeumol       Date:  2006-07       Impact factor: 4.872

3.  Percutaneous image-guided cutting-needle biopsy of the pleura in the presence of a suspected malignant effusion.

Authors:  R F Adams; F V Gleeson
Journal:  Radiology       Date:  2001-05       Impact factor: 11.105

4.  The utility of ultrasound-guided thoracentesis and pleural biopsy in undiagnosed pleural exudates.

Authors:  Coenraad Frederik N Koegelenberg; Elvis Malcom Irusen; Florian von Groote-Bidlingmaier; Johannes Willem Bruwer; Enas Mansour A Batubara; Andreas Henri Diacon
Journal:  Thorax       Date:  2015-05-21       Impact factor: 9.139

5.  Image-guided pleural biopsy: diagnostic yield and complications.

Authors:  R E Benamore; K Scott; C J Richards; J J Entwisle
Journal:  Clin Radiol       Date:  2006-08       Impact factor: 2.350

6.  Comparison of needle biopsy with cytologic analysis for the evaluation of pleural effusion: analysis of 414 cases.

Authors:  U B Prakash; H M Reiman
Journal:  Mayo Clin Proc       Date:  1985-03       Impact factor: 7.616

Review 7.  Pleural controversies: image guided biopsy vs. thoracoscopy for undiagnosed pleural effusions?

Authors:  Giles Dixon; Duneesha de Fonseka; Nick Maskell
Journal:  J Thorac Dis       Date:  2015-06       Impact factor: 2.895

8.  Tru-cut needle pleural biopsy and cytology as the initial procedure in the evaluation of pleural effusion.

Authors:  Maribel Botana Rial; Andrés Briones Gómez; José Ramón Ferrando Gabarda; José Fernando Cifuentes Ruiz; María Juliana Guarín Corredor; Nuria Manchego Frach; Enrique Cases Viedma
Journal:  Arch Bronconeumol       Date:  2014-02-24       Impact factor: 4.872

9.  CT-guided core needle biopsy of pleural lesions: evaluating diagnostic yield and associated complications.

Authors:  Xiang-Ke Niu; Anup Bhetuwal; Han-Feng Yang
Journal:  Korean J Radiol       Date:  2015-01-09       Impact factor: 3.500

10.  Combined ultrasound-guided cutting-needle biopsy and standard pleural biopsy for diagnosis of malignant pleural effusions.

Authors:  Jinlin Wang; Xinghua Zhou; Xiaohong Xie; Qing Tang; Panxiao Shen; Yunxiang Zeng
Journal:  BMC Pulm Med       Date:  2016-11-17       Impact factor: 3.317

View more
  3 in total

1.  A novel PDX modeling strategy and its application in metabolomics study for malignant pleural mesothelioma.

Authors:  Zhongjian Chen; Chenxi Yang; Zhenying Guo; Siyu Song; Yun Gao; Ding Wang; Weimin Mao; Junping Liu
Journal:  BMC Cancer       Date:  2021-11-17       Impact factor: 4.430

2.  Comparison of Diagnostic Yield and Complications in Ultrasound-Guided Closed Pleural Biopsy Versus Thoracoscopic Pleural Biopsy in Undiagnosed Exudative Pleural Effusion.

Authors:  Gopal Durgeshwar; Prasanta R Mohapatra; Shakti K Bal; Pritinanda Mishra; Sourin Bhuniya; Manoj K Panigrahi; Vedala Raja M Acharyulu; Sudip Ghosh; Satya P Mantha; Ananda Dutta
Journal:  Cureus       Date:  2022-04-04

3.  Diagnostic ability and its influenced factors of ultrasound-guided percutaneous pleural needle biopsy diagnosis for malignant pleural mesothelioma.

Authors:  Yuxin Zhang; Jiaxin Tang; Xinghua Zhou; Wuxi Chen; Shiyu Zhang; Yuqin Li; Dazhi Zhou; Liantu He; Qing Tang
Journal:  Front Surg       Date:  2022-09-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.