Effect of metal reconstruction plates on cobalt-60 dose distribution: a predictive formula and clinical implications.

E Melian1, M Fatyga, P Lam, M Steinberg, S P Reddy, G J Petruzzelli, G P Glasgow.   

Abstract

PURPOSE: We sought to create a predictive formula for the dose perturbations caused by head and neck reconstruction plates in the delivery of postoperative radiotherapy with 60Co beams.
MATERIALS AND METHODS: The dose perturbation effects of Vitallium and Titanium reconstruction plates and flat metal plates of aluminum (13Al), stainless steel (26Fe), tin (50Sn) and lead (82Pb) irradiated with a 60Co beam were measured in polystyrene phantoms using a film dosimetry system. We then used these results to create formulas to predict the effect of a metal reconstruction plate dependent upon its effective atomic number.
RESULTS: Percentage dose increases secondary to back scattering were 10% at 1 mm in front of the Vitallium plate and 40% at the plate while the percentage dose decrease was 29% at the plate and 10% 1 mm behind the plate. For the Titanium plate, the percentage dose increase was 5% at 1 mm in front the plate and 25% at the plate while the percentage dose decrease was 20% at the plate and 5% 1 mm behind the plate. For flat plates the percentage dose increases and decreases, respectively, at the plate surfaces were: 13Al (8%, 6%), 26Fe (35%, 16%), 50Sn (60%, 24%), and 82Pb (85%, 13%). A second order polynomial predicting the back scatter and shadowing effects was created, Y = a + bZ + cZ2, where Z is the effective atomic number of the plate while a, b, and c are the following constants: for back scatter a = 0.854 +/- 0.082, b = 0.0212 +/- 0.0044, c = -0.00011 +/- 0.00004 and for shadowing a = 1.108 +/- 0.021, b = -0.0141 +/- 0.0011, c = 0.00014 +/- 0.00001.
CONCLUSIONS: It is possible to predict the effect of a metal reconstruction plate upon the delivered postoperative radiotherapy dose. The dose perturbations around the plate only exist for a few millimeters, but this is substantially greater than the thickness of a normal tissue or tumor cell. Perhaps a coating of a low effective atomic number, biologically inert, substance might allow for greater dose homogeneity and decrease the risks of plate failure or tumor recurrence.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10348305     DOI: 10.1016/s0360-3016(99)00065-6

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Estimation of dose enhancement to soft tissue due to backscatter radiation near metal interfaces during head and neck radiothearpy - A phantom dosimetric study with radiochromic film.

Authors:  Rajesh Ashok Kinhikar; Chandrashekhar M Tambe; Kalpana Patil; Mahadev Mandavkar; Deepak D Deshpande; Rajendra Gujjalanavar; Prabha Yadav; Ashwini Budrukkar
Journal:  J Med Phys       Date:  2014-01

2.  Effects of titanium mesh implant on dosimetry during Gamma Knife radiosurgery.

Authors:  Joseph T Rakowski; Karen Chin; Sandeep Mittal
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.