| Literature DB >> 10336065 |
S Maison1, C Micheyl, L Collet.
Abstract
It is well established that low-level broad band noise can elicit an amplitude decrease in evoked otoacoustic emissions recorded in the opposite ear. However, the influence of the temporal characteristics of the contralateral stimulus on this effect remains largely unknown. In the present study, otoacoustic emissions evoked by 60 dB SPL clicks were recorded in 19 normal-hearing subjects using the Otodynamics IL088, successively in absence and presence of a contralateral noise that was either steady or modulated sinusoidally in amplitude at different depths (from 25% to 100% in 25 point steps) and rates (from 50 Hz to 800 Hz in half-octave steps). The energy was kept constant whatever the modulation depth. The results showed that the evoked otoacoustic-emission attenuation effect induced by contralateral stimulation varied depending on the modulation depth and frequency of the contralateral amplitude-modulated noise. The largest suppression effect was observed at the 100 Hz modulation frequency and the 100% modulation depth. The 50 Hz modulation resulted in less suppression than with unmodulated noise. An interpretation of these results in terms of the influence of temporal amplitude fluctuations falling within a certain range on medial olivocochlear bundle activity is discussed.Entities:
Mesh:
Year: 1999 PMID: 10336065 DOI: 10.1016/s0306-4522(98)00608-3
Source DB: PubMed Journal: Neuroscience ISSN: 0306-4522 Impact factor: 3.590