Electronic length measurement using small and large files in enlarged canals.

H Q Nguyen1, A Y Kaufman, R C Komorowski, S Friedman.   

Abstract

Electronic apex locators are frequently used attached to a small size endodontic file; however, the effect on the measurement of the relative diameters of the file and the root canal has not been clarified. In this study, the length of enlarged canals was measured using small size files and files matching the canal diameter to observe a possible discrepancy. The accuracy of electronic length control during canal preparation with rotary files was also assessed. The root canals in 21 extracted, single rooted teeth were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an alginate mold. The initial canal length (IL) was measured with the Root ZX apex locator by negotiating a size 10 file to the apical constriction. The canal was enlarged to size 60 with rotary files while the length was continuously controlled with the apex locator. Then, the final length measurements were obtained with a size 10 file and a size 60 file (FL-10 and FL-60, respectively). The average values of IL, FL-10 and FL-60 were calculated and compared using Repeated Measures Analysis of Variance followed by Tukey's Studentized Range test (P < 0.05). Using composite resin, the size 60 files were secured at the FL-60 length, the teeth were removed from the alginate mold, stained with Picroformal DI Buoin stain and the position of the file tip was observed histomorphometrically after the apical 4 mm of the canal was exposed by grinding the buccal aspect of the root. The IL was 0.45 mm shorter than AL (P < 0.05). The differences between FL-10, FL-60 and IL were not statistically significant. Histomorphometrically, the apical constriction was absent in all the teeth, but the file tips were confined within the root. This study concluded that the Root ZX indicated the location of an apical constriction even when the anatomic constriction was eliminated. In the enlarged canals, length measurements obtained with small and large size files were comparable.

Entities:  

Mesh:

Year:  1996        PMID: 10332234     DOI: 10.1111/j.1365-2591.1996.tb01398.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  12 in total

1.  Formulating a regression equation for determination of working length in primary molars using apex locators: a clinical study.

Authors:  A Dandempally; R Muppa; M K Duddu; P Bhupatiraju; S Nallanchakrava
Journal:  Eur Arch Paediatr Dent       Date:  2013-06-18

2.  An ex vivo comparison of working length determination by three electronic root canal length measurement devices integrated into endodontic rotary motors.

Authors:  Manal Maree Ali; Ronald Wigler; Shaul Lin; Arieh Y Kaufman
Journal:  Clin Oral Investig       Date:  2016-07-09       Impact factor: 3.573

3.  Evaluation of the Working Length Determination Accuracy by Cone-beam Computed Tomography in Primary Teeth.

Authors:  John Shibin; Prathima Gs; Suganya M; Nandhakumar S; Sanguida Adimoulame; Kavitha M
Journal:  Int J Clin Pediatr Dent       Date:  2022

4.  Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study.

Authors:  Rakesh Reddy Chukka; Malati Devi Bellam; Narender Reddy Marukala; Sainath Dinapadu; Naresh Kumar Konda; Jithender Nagilla
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

5.  Effect of pre-flaring and file size on the accuracy of two electronic apex locators.

Authors:  Manoel Brito-Júnior; Carla Cristina Camilo; Gil Moreira-Júnior; Jesus Djalma Pecora; Manoel Damião Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

6.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

7.  A Comparative Evaluation of Accuracy of New-generation Electronic Apex Locator with Conventional Radiography to determine Working Length in Primary Teeth: An in vivo Study.

Authors:  K Vidya Bhat; Prakashchandra Shetty; Latha Anandakrishna
Journal:  Int J Clin Pediatr Dent       Date:  2017-02-27

8.  An in vitro comparison of root canal length determination by DentaPort ZX and iPex apex locators.

Authors:  Nikhil Puri; Rupali Chadha; Pragya Kumar; Komal Puri
Journal:  J Conserv Dent       Date:  2013-11

9.  Working Length Determination of Root Canal of Young Permanent Tooth: An In vitro Study.

Authors:  A Diwanji; As Rathore; R Arora; V Dhar; A Madhusudan; J Doshi
Journal:  Ann Med Health Sci Res       Date:  2014-07

10.  Comparative evaluation of the accuracy of two electronic apex locators in determining the working length in teeth with simulated apical root resorption: An in vitro study.

Authors:  Vidya Saraswathi; Archit Kedia; Tina Puthen Purayil; Vasudev Ballal; Aakriti Saini
Journal:  J Conserv Dent       Date:  2016 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.