| Literature DB >> 10328769 |
U Schaefer1, W Boos, R Takors, D Weuster-Botz.
Abstract
An automated sampling device coupled to a stirred tank reactor was developed for monitoring intracellular metabolite dynamics. Sample flasks fixed in transport magazines were moved by a step engine in a way that each sample flask was filled within 220 ms, resulting in a sampling rate of 4.5 s-1. Rapid inactivation of the metabolism was achieved by spraying the samples into 60% methanol at -50 degrees C. After centrifugation of the quenched cells at -20 degrees C the metabolites were extracted with perchloric acid and analyzed biochemically or with HPLC. The automated sampling device was applied for investigation of the intracellular metabolite dynamics of glycolysis in Escherichia coli after rapid glucose addition to a glucose-limited steady-state culture. For the first time oscillations of intracellular metabolite concentrations like glucose-6-phosphate, phosphoenolpyruvate, glyceraldehyde 3-phosphate, dihydroxyacetonphosphate, 3-phosphoglycerate, and pyruvate were quantified on a subseconds to seconds scale in E. coli. As an example, the kinetics of the decomposition of fructose 1, 6-bisphosphate to glyceraldehyde 3-phosphate and dihydroxyacetonphosphate were investigated by use of a well-known mechanistic kinetic model and the measured in vivo metabolite dynamics. Copyright 1999 Academic Press.Entities:
Mesh:
Substances:
Year: 1999 PMID: 10328769 DOI: 10.1006/abio.1999.4048
Source DB: PubMed Journal: Anal Biochem ISSN: 0003-2697 Impact factor: 3.365