Literature DB >> 10326856

An end-to-end pancreaticojejunostomy using a mechanical purse-string device.

M M Murr1, D M Nagorney.   

Abstract

Pancreatic-jejunal anastomosis leaks are a major cause of morbidity and mortality after pancreaticoduodenectomy. We have used a mechanical purse-string device to secure the jejunum to the intussuscepted pancreatic stump in 17 patients. A major leak developed in 1 patient and minor leaks developed in 2 patients, all of which were managed nonoperatively. This technique is expeditious and safe.

Entities:  

Mesh:

Year:  1999        PMID: 10326856     DOI: 10.1016/s0002-9610(99)00053-7

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  1 in total

1.  Risk-adapted anastomosis for partial pancreaticoduodenectomy reduces the risk of pancreatic fistula: a pilot study.

Authors:  Marco Niedergethmann; Niloufar Dusch; Rizky Widyaningsih; Christel Weiss; Peter Kienle; Stefan Post
Journal:  World J Surg       Date:  2010-07       Impact factor: 3.352

  1 in total