A field comparison of two methods for sampling lead in household dust.

D Q Rich1, L M Yiin, G G Rhoads, D H Glueck, C Weisel, P J Lioy.   

Abstract

Comparability of dust lead measurements has been a difficult problem due to different sampling and analysis techniques. This paper compares two dust sampling techniques, the U.S. Department of Housing and Urban Development (HUD) dust wipe method and the Lioy, Wainman, Weisel (LWW) sampler. The HUD method specifies using a moist towelette to pick up as much dust as possible in a specified area and estimates total lead loading. The LWW sampler collects the dust on preweighed wetted filter media, and provides greater standardization of the sampling path and pressure applied. LWW samples were analyzed using inductively coupled plasma mass spectronomy (no samples below minimum detection limit), while HUD samples were analyzed using flame atomic absorption (32% of samples below minimum detection limit). A bootstrapping technique was used in the analysis to contend with those HUD samples below the minimum detection limit. Mixed model equations were generated to predict HUD values from LWW results, and to examine the effects of sampling location, time, and method. The results indicate that the two samplers performed similarly under field conditions, although the LWW sampler produced consistently lower lead loading estimates. LWW values that predicted HUD lead clearance values of 100 micrograms/ft2 for floors and 500 micrograms/ft2 for window sills were 72 micrograms/ft2 and 275 micrograms/ft2, respectively. To examine internal reproducibility, duplicate samples were taken using both the HUD and LWW methods. Correlation results within paired samples indicated a statistically significantly higher (p < 0.001) internal reproducibility for lead loading, for the LWW sampler (r = 0.87), than for the HUD method (r = 0.71). Some of the differences appeared to be related to the analytical methods.

Mesh:

Substances:

Year:  1999        PMID: 10321350     DOI: 10.1038/sj.jea.7500006

Source DB:  PubMed          Journal:  J Expo Anal Environ Epidemiol        ISSN: 1053-4245


  3 in total

Review 1.  Dust: a metric for use in residential and building exposure assessment and source characterization.

Authors:  Paul J Lioy; Natalie C G Freeman; James R Millette
Journal:  Environ Health Perspect       Date:  2002-10       Impact factor: 9.031

2.  Hydroxylated PCB metabolites and PCBs in serum from pregnant Faroese women.

Authors:  Britta Fängström; Maria Athanasiadou; Philippe Grandjean; Pál Weihe; Ake Bergman
Journal:  Environ Health Perspect       Date:  2002-09       Impact factor: 9.031

3.  Comparison of home lead dust reduction techniques on hard surfaces: the New Jersey assessment of cleaning techniques trial.

Authors:  David Q Rich; George G Rhoads; Lih-Ming Yiin; Junfeng Zhang; Zhipeng Bai; John L Adgate; Peter J Ashley; Paul J Lioy
Journal:  Environ Health Perspect       Date:  2002-09       Impact factor: 9.031

  3 in total