Long-lasting osseointegration of immediately loaded, bar-connected TPS screws after 12 years of function: a histologic case report of a 95-year-old patient.

P D Ledermann1, R K Schenk, D Buser.   

Abstract

The present case report provides histologic findings on four titanium plasma-sprayed screw implants after 12 years of incorporation and functional load in a 95-year-old patient. At the time of implant placement, the four implants were immediately connected with a bar and functionally loaded with a bar-supported overdenture. The histologic analysis demonstrated excellent osseointegration in either cortical or cancellous bone for all implants. The histomorphometric analysis showed direct bone-implant contact of approximately 70% to 80% at the interface. Close to the implant surface, signs of ongoing bone remodeling activities were present. The present histologic case report confirms the validity of the applied treatment concept--to immediately load titanium implants with a titanium plasma-sprayed surface in the anterior region of the mandible--if a minimum of four implants can be inserted and if the four implants are splinted with a bar.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10321170

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  5 in total

1.  Comparative study of immediate functional loading and immediate non-functional loading of monocortical implants.

Authors:  J P Singh; A K Gupta; R K Dhiman; S K Roy Chowdhury
Journal:  Med J Armed Forces India       Date:  2014-03-12

2.  The use of light/chemically hardened polymethylmethacrylate, polyhydroxyethylmethacrylate, and calcium hydroxide graft material in combination with polyanhydride around implants in minipigs: part I: immediate stability and function.

Authors:  Hatice Hasturk; Alpdogan Kantarci; Mazen Ghattas; Marcella Schmidt; Russell A Giordano; Arthur Ashman; Thomas G Diekwisch; Thomas Van Dyke
Journal:  J Periodontol       Date:  2011-02-22       Impact factor: 6.993

3.  Peri-implant bone reactions around immediately loaded conical implants with different prosthetic suprastructures: histological and histomorphometrical study on minipigs.

Authors:  Bartolomeo Assenza; Antonio Scarano; Vittoria Perrotti; Iole Vozza; Alessandro Quaranta; Manlio Quaranta; Adriano Piattelli; Giovanna Iezzi
Journal:  Clin Oral Investig       Date:  2009-06-04       Impact factor: 3.573

4.  Peri-implant bone tissues around retrieved human implants after time periods longer than 5 years: a retrospective histologic and histomorphometric evaluation of 8 cases.

Authors:  Giovanna Iezzi; Adriano Piattelli; Carlo Mangano; Jamil A Shibli; Giovanni Vantaggiato; Massimo Frosecchi; Claudio Di Chiara; Vittoria Perrotti
Journal:  Odontology       Date:  2012-08-28       Impact factor: 2.634

5.  Application of Orthodontic Immediate Force on Dental Implants: Histomorphologic and Histomorphometric Assessment.

Authors:  Mansour Rismanchian; Sayed Hamid Raji; Sayed Mohammad Razavi; Danesh Teimouri Rick; Amin Davoudi
Journal:  Ann Maxillofac Surg       Date:  2017 Jan-Jun
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.