Literature DB >> 10227485

Teleradiology using low-cost consumer-oriented computer hardware and software.

L Pysher1, C Harlow.   

Abstract

OBJECTIVE: Our study was a practice audit to evaluate the feasibility of using low-cost, consumer-oriented computer hardware and software to perform after-hours teleradiology consisting predominantly of CT images.
MATERIALS AND METHODS: We performed a prospective study of 137 consecutive emergent CT scans of the head obtained after business hours. The scans were digitized using a consumer-oriented, low-cost flatbed scanner and sent to on-call radiologists for interpretation. Preliminary reports were then telephoned to the referring physician. Another radiologist who was unaware of the preliminary report evaluated the hard-copy images.
RESULTS: Combining cases with minor discrepancies and those of complete agreement, we found a 96% concordance. Five major discrepancies (4%) were found. No adverse outcomes resulted. Discrepancies were caused by interobserver variation rather than by the quality of the digitized images.
CONCLUSION: Our results support the use of consumer-oriented, low-cost computer hardware and software for emergent teleradiology in which most of the transmitted studies consist of CT images of the head.

Mesh:

Year:  1999        PMID: 10227485     DOI: 10.2214/ajr.172.5.10227485

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Overnight resident preliminary interpretations on CT examinations: should the process continue?

Authors:  William M Strub; Achala A Vagal; Thomas Tomsick; Jonathan S Moulton
Journal:  Emerg Radiol       Date:  2006-07-25

Review 2.  Tele-Health and neurology: what is possible?

Authors:  Francesca Timpano; Lilla Bonanno; Alessia Bramanti; Fabio Pirrotta; Letteria Spadaro; Placido Bramanti; Pietro Lanzafame
Journal:  Neurol Sci       Date:  2013-02-21       Impact factor: 3.307

3.  Radiology resident evaluation of head CT scan orders in the emergency department.

Authors:  William K Erly; William G Berger; Elizabeth Krupinski; Joachim F Seeger; John A Guisto
Journal:  AJNR Am J Neuroradiol       Date:  2002-01       Impact factor: 3.825

  3 in total