Literature DB >> 10225083

A comparison of the monitors INVOS 3100 and NIRO 500 in detecting changes in cerebral oxygenation.

G Grubhofer1, W Tonninger, P Keznickl, P Skyllouriotis, M Ehrlich, M Hiesmayr, A Lassnigg.   

Abstract

BACKGROUND: Measurements of cerebral haemoglobin oxygenation of 2 near-infrared spectroscopy devices (INVOS 3100 and NIRO 500) were compared during and after hypocapnia.
METHODS: Fifteen awake, healthy volunteers, who hyperventilated to obtain end-tidal CO2 (EtCO2) values of approximately 20 mmHg, were studied. During hyperventilation and 8 min thereafter, EtCO2, INVOS 3100 (RSO2 = regional cerebral oxygenation) and NIRO 500 recordings (HbO2 = oxyhaemoglobin, Hb = deoxyhaemoglobin, Hb-diff = HbO2-Hb, CtO2 = oxidised cytochrome oxidase aa3) were analysed.
RESULTS: Hyperventilation induced a significant decline in EtCO2 from 30.5 to 14.7 mmHg (P < 0.001) and RSO2 from 67.1% to 62.7% (P = 0.025). At hypocapnia, only Hb (+1.61 +/- 0.48 mumol/L; P < 0.001) and Hb-diff (-3.01 +/- 2.0 mumol/L; P < 0.001) indicated a decline in cerebral haemoglobin oxygenation. Within 8 min after hyperventilation, both EtCO2 and RSO2 normalised to values insignificantly different from baseline. In contrast, Hb and Hb-diff remained significantly different (Hb: +2.52 +/- 1.28 mumol/l; P < 0.001, Hb-diff: -4.31 +/- 4.0 mumol/L; P < 0.001). A correlation with EtCO2 was found for RSO2 (R = 0.35; P < 0.001) and CtO2 (R = 0.42; P < 0.001). All volunteers were continuously awake and none presented clinical symptoms of cerebral hypoxia.
CONCLUSION: Changes in cerebral haemoglobin oxygenation state were reflected more accurately by INVOS 3100 than NIRO 500. The cause may be the different technology of the monitors, since INVOS 3100 eliminates the contribution of extracranial oxygenation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10225083     DOI: 10.1034/j.1399-6576.1999.430417.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  12 in total

1.  Comparison of two spatially resolved NIRS oxygenation indices.

Authors:  Roy E Gagnon; Andrew J Macnab; Faith A Gagnon; Derek Blackstock; Jacques G LeBlanc
Journal:  J Clin Monit Comput       Date:  2002-12       Impact factor: 2.502

2.  Comparison of Cerebral Oximeter and Pulse Oximeter Values in the First 72 Hours in Premature, Asphyctic and Healthy Newborns.

Authors:  A Kaya; M Okur; E Sal; E Peker; M Köstü; O Tuncer; E Kırımi
Journal:  West Indian Med J       Date:  2014-09-03       Impact factor: 0.171

3.  Cerebral desaturation during shoulder arthroscopy: a prospective observational study.

Authors:  Dane Salazar; Benjamin W Sears; John Andre; Pietro Tonino; Guido Marra
Journal:  Clin Orthop Relat Res       Date:  2013-04-19       Impact factor: 4.176

4.  Multichannel wearable fNIRS-EEG system for long-term clinical monitoring.

Authors:  Ali Kassab; Jérôme Le Lan; Julie Tremblay; Phetsamone Vannasing; Mahya Dehbozorgi; Philippe Pouliot; Anne Gallagher; Frédéric Lesage; Mohamad Sawan; Dang Khoa Nguyen
Journal:  Hum Brain Mapp       Date:  2017-10-23       Impact factor: 5.038

5.  Evaluation of splanchnic oximetry, Doppler flow velocimetry in the superior mesenteric artery and feeding tolerance in very low birth weight IUGR and non-IUGR infants receiving bolus versus continuous enteral nutrition.

Authors:  Valentina Bozzetti; Giuseppe Paterlini; Valeria Meroni; Paola DeLorenzo; Diego Gazzolo; Frank Van Bel; Gerard H A Visser; MariaGrazia Valsecchi; Paolo E Tagliabue
Journal:  BMC Pediatr       Date:  2012-07-24       Impact factor: 2.125

6.  Maintaining Gait Performance by Cortical Activation during Dual-Task Interference: A Functional Near-Infrared Spectroscopy Study.

Authors:  Chia-Feng Lu; Yan-Ci Liu; Yea-Ru Yang; Yu-Te Wu; Ray-Yau Wang
Journal:  PLoS One       Date:  2015-06-16       Impact factor: 3.240

7.  Multi-channel multi-distance broadband near-infrared spectroscopy system to measure the spatial response of cellular oxygen metabolism and tissue oxygenation.

Authors:  Phong Phan; David Highton; Jonathan Lai; Martin Smith; Clare Elwell; Ilias Tachtsidis
Journal:  Biomed Opt Express       Date:  2016-10-05       Impact factor: 3.732

Review 8.  Monitoring Cerebral Oxygenation in Neonates: An Update.

Authors:  Laura Marie Louise Dix; Frank van Bel; Petra Maria Anna Lemmers
Journal:  Front Pediatr       Date:  2017-03-14       Impact factor: 3.418

9.  Cerebral Near Infrared Spectroscopy Monitoring in Term Infants With Hypoxic Ischemic Encephalopathy-A Systematic Review.

Authors:  Subhabrata Mitra; Gemma Bale; Judith Meek; Ilias Tachtsidis; Nicola J Robertson
Journal:  Front Neurol       Date:  2020-05-27       Impact factor: 4.003

10.  Cytochrome c oxidase response to changes in cerebral oxygen delivery in the adult brain shows higher brain-specificity than haemoglobin.

Authors:  Christina Kolyva; Arnab Ghosh; Ilias Tachtsidis; David Highton; Chris E Cooper; Martin Smith; Clare E Elwell
Journal:  Neuroimage       Date:  2013-05-23       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.