A wearable tremor-suppression orthosis.

J Kotovsky1, M J Rosen.   

Abstract

The Viscous Beam is a wearable tremor-suppression orthosis that applies viscous resistance to motion of the wrist in flexion and extension. The orthosis reduces tremor amplitude and is small enough to be worn under the sleeve of a shirt. Hand and forearm cuffs couple the damper to the user. The cuffs permit full thumb and finger motion, wrist flexion and extension, and forearm pronation and supination. Damping is provided by a constrained-layer-damping (CLD) system, distinct in that it can damp large rotary deflections through a small bending radius. A bending-plate transmission linearly converts wrist extension/flexion to rectilinear translation within the damper. Bending deformation of two plates held a fixed distance apart within the transmission results in relative displacement along the lengths of the plates. A viscous fluid incorporated between the plates provides shear damping. Silicone fluids with viscosities as high as 10 million centistokes (cS) and shear layers as thin as 0.76 mm have been tested. With these parameter values, damping constants as high as 2.0x10(-3) N-m/(degrees/s) have been measured. This testing was conducted with strain rates as high as 4,580 degrees/s. The elastic stiffness of this beam was measured to be 4.1x10(-2) N-m/degrees.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10220215

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  14 in total

1.  Design of a noninvasive and smart hand tremor attenuation system with active control: a simulation study.

Authors:  Mahdi Abbasi; Aref Afsharfard; Roya Arasteh; Javad Safaie
Journal:  Med Biol Eng Comput       Date:  2018-01-03       Impact factor: 2.602

2.  Distribution of tremorogenic activity among the major superficial muscles of the upper limb in persons with Essential tremor.

Authors:  David J Standring; Adam C Pigg; Johanna Thompson-Westra; Karin Mente; Carine W Maurer; Dietrich Haubenberger; Mark Hallett; Steven K Charles
Journal:  Clin Neurophysiol       Date:  2022-07-16       Impact factor: 4.861

Review 3.  Rationale and Evidence for Peripheral Nerve Stimulation for Treating Essential Tremor.

Authors:  Aparna Wagle Shukla
Journal:  Tremor Other Hyperkinet Mov (N Y)       Date:  2022-06-14

Review 4.  Joystick control for powered mobility: current state of technology and future directions.

Authors:  Brad E Dicianno; Rory A Cooper; John Coltellaro
Journal:  Phys Med Rehabil Clin N Am       Date:  2010-02       Impact factor: 1.784

5.  Vib-bracelet: a passive absorber for attenuating forearm tremor.

Authors:  Eran Buki; Reuven Katz; Miriam Zacksenhouse; Ilana Schlesinger
Journal:  Med Biol Eng Comput       Date:  2017-11-04       Impact factor: 2.602

6.  Distribution of tremor among the major degrees of freedom of the upper limb in subjects with Essential Tremor.

Authors:  Adam C Pigg; Johanna Thompson-Westra; Karin Mente; Carine W Maurer; Dietrich Haubenberger; Mark Hallett; Steven K Charles
Journal:  Clin Neurophysiol       Date:  2020-09-02       Impact factor: 3.708

7.  Biomechanical loading as an alternative treatment for tremor: a review of two approaches.

Authors:  Eduardo Rocon; Juan Álvaro Gallego; Juan Manuel Belda-Lois; Julián Benito-León; José Luis Pons
Journal:  Tremor Other Hyperkinet Mov (N Y)       Date:  2012-10-10

8.  Real-time estimation of pathological tremor parameters from gyroscope data.

Authors:  Juan A Gallego; Eduardo Rocon; Javier O Roa; Juan C Moreno; José L Pons
Journal:  Sensors (Basel)       Date:  2010-03-16       Impact factor: 3.576

9.  Mechanical suppression of essential tremor.

Authors:  Eduardo Rocon; Mario Manto; Jose Pons; Stephane Camut; Juan Manuel Belda
Journal:  Cerebellum       Date:  2007       Impact factor: 3.648

10.  Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression.

Authors:  Gil Herrnstadt; Carlo Menon
Journal:  Front Bioeng Biotechnol       Date:  2016-03-31
View more