Literature DB >> 10217878

The effect of artifact rejection by signal-space projection on source localization accuracy in MEG measurements.

G Nolte1, G Curio.   

Abstract

The consequences of artifact suppression by means of signal-space projection on dipole localization accuracy for magnetoencephalography measurements are studied. Approximate analytical formulas, equivalent to the Cramer-Rao bound, are presented and verified by Monte Carlo simulations which relate the increase of localization error for individual coordinates to the similarity of the artifact field and respective (contravariant) quadrupole fields obtained by differentiating the dipole field with respect to its origin. The expressions simplify significantly for dipoles placed below the center of the measuring system giving rise to highly symmetric field patterns. Formulas are presented both for single- and for multiple-artifact rejection. As illustrative examples artifact fields are constructed which a) lead to highly decreasing signal-to-noise ratio and goodness-of-fit (GOF), while the localization error is unaffected for all coordinates and b) lead to an increase of localization error while the SNR and the GOF stays constant. Finally, the rich structure of localization error increase is demonstrated for a class of artifact fields originating from artifact current dipoles.

Entities:  

Mesh:

Year:  1999        PMID: 10217878     DOI: 10.1109/10.752937

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  13 in total

1.  Denoising based on time-shift PCA.

Authors:  Alain de Cheveigné; Jonathan Z Simon
Journal:  J Neurosci Methods       Date:  2007-06-08       Impact factor: 2.390

2.  The brain's resting-state activity is shaped by synchronized cross-frequency coupling of neural oscillations.

Authors:  Esther Florin; Sylvain Baillet
Journal:  Neuroimage       Date:  2015-02-11       Impact factor: 6.556

Review 3.  Subspace-based interference removal methods for a multichannel biomagnetic sensor array.

Authors:  Kensuke Sekihara; Srikantan S Nagarajan
Journal:  J Neural Eng       Date:  2017-08-18       Impact factor: 5.379

4.  Parameterizing neural power spectra into periodic and aperiodic components.

Authors:  Thomas Donoghue; Matar Haller; Erik J Peterson; Paroma Varma; Priyadarshini Sebastian; Richard Gao; Torben Noto; Antonio H Lara; Joni D Wallis; Robert T Knight; Avgusta Shestyuk; Bradley Voytek
Journal:  Nat Neurosci       Date:  2020-11-23       Impact factor: 24.884

5.  Electromyogenic Artifacts and Electroencephalographic Inferences Revisited.

Authors:  Brenton W McMenamin; Alexander J Shackman; Lawrence L Greischar; Richard J Davidson
Journal:  Neuroimage       Date:  2010-08-02       Impact factor: 6.556

6.  Noise cancellation for a whole-head magnetometer-based MEG system in hospital environment.

Authors:  Limin Sun; Matti S Hämäläinen; Yoshio Okada
Journal:  Biomed Phys Eng Express       Date:  2018-08-07

7.  Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG.

Authors:  Brenton W McMenamin; Alexander J Shackman; Jeffrey S Maxwell; David R W Bachhuber; Adam M Koppenhaver; Lawrence L Greischar; Richard J Davidson
Journal:  Neuroimage       Date:  2009-10-13       Impact factor: 6.556

8.  Dual signal subspace projection (DSSP): a novel algorithm for removing large interference in biomagnetic measurements.

Authors:  Kensuke Sekihara; Yuya Kawabata; Shuta Ushio; Satoshi Sumiya; Shigenori Kawabata; Yoshiaki Adachi; Srikantan S Nagarajan
Journal:  J Neural Eng       Date:  2016-04-11       Impact factor: 5.379

9.  Accounting for linear transformations of EEG and MEG data in source analysis.

Authors:  Joerg F Hipp; Markus Siegel
Journal:  PLoS One       Date:  2015-04-02       Impact factor: 3.240

10.  The Processing of Somatosensory Information Shifts from an Early Parallel into a Serial Processing Mode: A Combined fMRI/MEG Study.

Authors:  Carsten M Klingner; Stefan Brodoehl; Ralph Huonker; Otto W Witte
Journal:  Front Syst Neurosci       Date:  2016-12-20
View more