Literature DB >> 10212341

Validation of pulse dynamic blood pressure measurement by auscultation.

.   

Abstract

BACKGROUND: The accurate measurement of arterial blood pressure is essential for the diagnosis and treatment of hypertension. The development of new automated methods of measurement that provide reliable determinations of blood pressure should be valuable in the assessment of hypertension not only in the clinic or hospital but also, in the home for self-monitoring.
DESIGN: We evaluated a noninvasive method for the measurement of systolic and diastolic blood pressures in 132 subjects.
METHODS: Measurements obtained using the pulse dynamic method of blood pressure determination were validated with simultaneous manual measurements. Two qualified nurses used Korotkoff sounds to determine systolic (phase I) and diastolic (phase IV) blood pressures according to the Association for the Advancement of Medical Instrumentation 1987 guidelines.
RESULTS: Inter-nurse variability was 2.7 +/- 4.1 mmHg (mean +/- SD) for systolic blood pressure and 4.0 +/- 3.7 mmHg for diastolic blood pressure and correlations were r = 0.98 and 0.94, respectively. We observed excellent agreement between auscultatory and pulse dynamic methods for systolic (127 +/- 21 versus 132 +/- 20 mmHg; r = 0.97) and diastolic (72 +/- 10 versus 71 +/- 10 mmHg; r = 0.89) blood pressures. Bland-Altman analysis demonstrated that there was a mean difference (reference-device) between the two methods of - mmHg (pulse dynamic value higher) and SD of 5 mmHg for systolic blood pressure and a mean difference of 1 mmHg (pulse dynamic value lower) and SD of 5 mmHg for diastolic blood pressure.
CONCLUSION: The results of this study demonstrate that this noninvasive method of measurement of blood pressure is accurate and reliable and should therefore be appropriate for the evaluation of hypertension both in the home and in clinical settings.

Entities:  

Year:  1998        PMID: 10212341

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  9 in total

1.  Reduced brachial artery distensibility in patients with type 1 diabetes.

Authors:  Philip Ljunggren; David M Maahs; Per Johansson; Johnny Ludvigsson; Laura Pyle; Rachel Sippl; R Paul Wadwa; Janet Snell-Bergeon
Journal:  J Diabetes Complications       Date:  2016-03-11       Impact factor: 2.852

2.  Smoking cessation program with exercise improves cardiovascular disease biomarkers in sedentary women.

Authors:  Tellervo Korhonen; Amy Goodwin; Petra Miesmaa; Elizabeth A Dupuis; Taru Kinnunen
Journal:  J Womens Health (Larchmt)       Date:  2011-06-15       Impact factor: 2.681

3.  Ventriculo-vascular interactions in patients with beta thalassaemia major.

Authors:  Y F Cheung; S Y Ha; G C F Chan
Journal:  Heart       Date:  2005-06       Impact factor: 5.994

4.  Polycyclic aromatic hydrocarbons, brachial artery distensibility and blood pressure among children residing near an oil refinery.

Authors:  Leonardo Trasande; Elaine M Urbina; Mamdouh Khoder; Mansour Alghamdi; Ibrahim Shabaj; Mohammed S Alam; Roy M Harrison; Magdy Shamy
Journal:  Environ Res       Date:  2014-11-20       Impact factor: 6.498

5.  Overweight and Hyperinsulinemia Provide Individual Contributions to Compromises in Brachial Artery Distensibility in Healthy Adolescents and Young Adults: Brachial Distensibility in Children.

Authors:  Elaine M Urbina; Judy A Bean; Stephen R Daniels; David D'Alessio; Lawrence M Dolan
Journal:  J Am Soc Hypertens       Date:  2007-06

6.  Arterial function of carotid and brachial arteries in postmenopausal vegetarians.

Authors:  Ta-Chen Su; Pao-Ling Torng; Jiann-Shing Jeng; Ming-Fong Chen; Chiau-Suong Liau
Journal:  Vasc Health Risk Manag       Date:  2011-08-23

7.  Gender differences in the relationships among obesity, adiponectin and brachial artery distensibility in adolescents and young adults.

Authors:  E M Urbina; P Khoury; L J Martin; D D'Alessio; L M Dolan
Journal:  Int J Obes (Lond)       Date:  2009-08-25       Impact factor: 5.095

8.  Effects of occupational noise exposure on 24-hour ambulatory vascular properties in male workers.

Authors:  Ta-Yuan Chang; Ta-Chen Su; Shou-Yu Lin; Ruei-Man Jain; Chang-Chuan Chan
Journal:  Environ Health Perspect       Date:  2007-11       Impact factor: 9.031

9.  Forest Bathing Is Better than Walking in Urban Park: Comparison of Cardiac and Vascular Function between Urban and Forest Parks.

Authors:  Tsung-Ming Tsao; Jing-Shiang Hwang; Sung-Tsun Lin; Charlene Wu; Ming-Jer Tsai; Ta-Chen Su
Journal:  Int J Environ Res Public Health       Date:  2022-03-15       Impact factor: 3.390

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.