Literature DB >> 10211559

The efficacy of technetium-99m-MIBI scan and intraoperative methylene blue staining for the localization of abnormal parathyroid glands.

H Takei1, Y Iino, K Endo, J Horiguchi, M Maemura, Y Koibuchi, Y Horii, T Yokoe, T Ishida, T Oyama, Y Morishita.   

Abstract

The efficacy of the technetium-99m-2-methoxyisobutylisonitrile (Tc-MIBI) scan and intraoperative methylene blue staining was analyzed in a consecutive series of 15 patients with primary hyperparathyroidism who underwent neck surgical exploration. A total of 17 abnormal parathyroid glands were removed, 7 of which were confirmed histologically as adenomas and 10 as hyperplasias. The Tc-MIBI scan and the thallium-201-technetium-99m subtraction (Tl/Tc) scan preoperatively localized 11 (69%) of 16, and 6 (40%) of 15 abnormal parathyroid glands, respectively. The Tc-MIBI scan correctly localized two ectopic abnormal parathyroid glands which were not localized by the Tl/Tc scan or ultrasonography (US). However, it also demonstrated false-positive accumulations caused by thyroid diseases in two patients. There were 4 abnormal parathyroid glands not detected by the preoperative imaging techniques, whereas all 17 abnormal parathyroid glands were stained with methylene blue, the infusion of which caused no adverse effects or toxicity. In conclusion, Tc-MIBI scanning and intraoperative methylene blue staining are effective techniques for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10211559     DOI: 10.1007/BF02483053

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  23 in total

1.  In vivo uptake of technetium-99M-sestamibi by parathyroid glands in comparison to surrounding tissues of the neck.

Authors:  G S Waters; G J Burke; J H Corley; J P Wei
Journal:  Am Surg       Date:  1997-02       Impact factor: 0.688

2.  An evaluation of the intraoperative staining technique using methylene blue for the detection of hyperplastic parathyroid glands.

Authors:  S Kobayashi; M Miyakawa; A Sugenoya; O Senga; G Kaneko; T Yokozawa; Y Kasuga; H Masuda; Y T Chang; F Iida
Journal:  Jpn J Surg       Date:  1988-11

3.  Parathyroid localization with technetium-99m-sestamibi: a prospective evaluation.

Authors:  C R McHenry; K Lee; J Saadey; D R Neumann; C B Esselstyn
Journal:  J Am Coll Surg       Date:  1996-07       Impact factor: 6.113

4.  Preoperative imaging of abnormal parathyroid glands in patients with hyperparathyroid disease using combination Tc-99m-pertechnetate and Tc-99m-sestamibi radionuclide scans.

Authors:  J P Wei; G J Burke; A R Mansberger
Journal:  Ann Surg       Date:  1994-05       Impact factor: 12.969

5.  A prospective trial evaluating a standard approach to reoperation for missed parathyroid adenoma.

Authors:  N Jaskowiak; J A Norton; H R Alexander; J L Doppman; T Shawker; M Skarulis; S Marx; A Spiegel; D L Fraker
Journal:  Ann Surg       Date:  1996-09       Impact factor: 12.969

6.  Parathyroid imaging with technetium-99m-sestamibi: preoperative localization and tissue uptake studies.

Authors:  M J O'Doherty; A G Kettle; P Wells; R E Collins; A J Coakley
Journal:  J Nucl Med       Date:  1992-03       Impact factor: 10.057

7.  Detection and localization of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase study)

Authors:  R Taillefer; Y Boucher; C Potvin; R Lambert
Journal:  J Nucl Med       Date:  1992-10       Impact factor: 10.057

8.  Value of technetium 99m sestamibi iodine 123 imaging in reoperative parathyroid surgery.

Authors:  C J Weber; J Vansant; N Alazraki; J Christy; N Watts; L S Phillips; K Mansour; W Sewell; W C McGarity
Journal:  Surgery       Date:  1993-12       Impact factor: 3.982

9.  Methylene blue for rapid identification of the parathyroids.

Authors:  N E Dudley
Journal:  Br Med J       Date:  1971-09-18

10.  Analysis of savings in operative time for primary hyperparathyroidism using localization with technetium 99m sestamibi scan.

Authors:  J P Wei; G J Burke
Journal:  Am J Surg       Date:  1995-11       Impact factor: 2.565

View more
  2 in total

Review 1.  Intraoperative adjuncts in surgery for primary hyperparathyroidism.

Authors:  Barney J Harrison; Frederic Triponez
Journal:  Langenbecks Arch Surg       Date:  2009-07-10       Impact factor: 3.445

Review 2.  Clinical value of parathyroid scintigraphy with technetium-99m methoxyisobutylisonitrile: discrepancies in clinical data and a systematic metaanalysis of the literature.

Authors:  Martin Gotthardt; Bodo Lohmann; Thomas M Behr; Artur Bauhofer; Christiane Franzius; Meike L Schipper; Maria Wagner; Helmut Höffken; Helmut Sitter; Matthias Rothmund; Klaus Joseph; Christoph Nies
Journal:  World J Surg       Date:  2003-11-26       Impact factor: 3.352

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.