Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging--initial experience.

W Kessler1, G Laub, S Achenbach, D Ropers, W Moshage, W G Daniel.   

Abstract

Gadolinium-enhanced, three-dimensional, breath-hold magnetic resonance (MR) coronary angiography was performed in two healthy volunteers and 11 patients suspected or known to have coronary artery disease. MR angiograms were compared with those obtained with retrospective respiratory gating. Of 52 main coronary arteries, 47 could be visualized with the breath-hold technique and 49 with the gating technique. Signal-to-noise and contrast-to-noise ratios were significantly higher with the breath-hold technique. Overall image quality was slightly lower with breath-hold imaging. With either technique, three of five, significant coronary stenoses were correctly identified.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10207446     DOI: 10.1148/radiology.210.2.r99fe38566

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Magnetic resonance imaging for the non-invasive detection of stenosis in coronary artery bypass grafts: clinical reality?

Authors:  E E van der Wall; S E Langerak
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

2.  Toward comparability of coronary magnetic resonance angiography: proposal for a standardized quantitative assessment.

Authors:  Martijn S Dirksen; Hildo J Lamb; Rob van der Geest; Albert de Roos
Journal:  Eur Radiol       Date:  2003-08-02       Impact factor: 5.315

3.  MRI in the detection of stenosis in coronary artery bypass grafts: are invasive techniques still needed?

Authors:  S E Langerak; E E van der Wall
Journal:  Neth Heart J       Date:  2003-01       Impact factor: 2.380

4.  Contrast-kinetics-resolved whole-heart coronary MRA using 3DPR.

Authors:  Peng Lai; Feng Huang; Yu Li; Sonia Nielles-Vallespin; Xiaoming Bi; Renate Jerecic; Debiao Li
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

5.  Three-dimensional breathhold magnetization-prepared TrueFISP: a pilot study for magnetic resonance imaging of the coronary artery disease.

Authors:  Richard M McCarthy; Vibhas S Deshpande; Nirat Beohar; Sheridan N Meyers; Steven M Shea; Jordin D Green; Xin Liu; Xiaoming Bi; F Scott Pereles; John Paul Finn; Charles J Davidson; James C Carr; Debiao Li
Journal:  Invest Radiol       Date:  2007-10       Impact factor: 6.016