Literature DB >> 10204887

Parameter estimation from Rician-distributed data sets using a maximum likelihood estimator: application to T1 and perfusion measurements.

O T Karlsen1, R Verhagen, W M Bovée.   

Abstract

General expressions are presented to calculate the maximum likelihood (ML) estimator and corresponding Fisher matrix for Rician-distributed data sets. This estimator results in the most precise, unbiased estimations of T1 from magnitude data sets, even when low signal-to-noise ratios (<6) are present. By optimizing the sample point distributions for inversion-recovery experiments, a 32% increase in precision of the estimated T1 is obtained, compared with a linear sampling scheme. Perfusion rates are estimated from combined data sets of the slice- and nonslice-selective inversion-recovery experiments, as obtained with the flow-sensitive alternating inversion recovery (FAIR) technique. The ML estimator for the combined data set results in the most precise, unbiased estimations of the perfusion rate. Error analysis shows that very high signal-to-noise ratios are required for precise estimation of perfusion rates from FAIR experiments.

Entities:  

Mesh:

Year:  1999        PMID: 10204887     DOI: 10.1002/(sici)1522-2594(199903)41:3<614::aid-mrm26>3.0.co;2-1

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Penumbra detection using PWI/DWI mismatch MRI in a rat stroke model with and without comorbidity: comparison of methods.

Authors:  Emma Reid; Delyth Graham; M Rosario Lopez-Gonzalez; William M Holmes; I Mhairi Macrae; Christopher McCabe
Journal:  J Cereb Blood Flow Metab       Date:  2012-06-06       Impact factor: 6.200

2.  Prediction of the estimated 5-year risk of sudden cardiac death and syncope or non-sustained ventricular tachycardia in patients with hypertrophic cardiomyopathy using late gadolinium enhancement and extracellular volume CMR.

Authors:  Maxim Avanesov; Julia Münch; Julius Weinrich; Lennart Well; Dennis Säring; Christian Stehning; Enver Tahir; Sebastian Bohnen; Ulf K Radunski; Kai Muellerleile; Gerhard Adam; Monica Patten; Gunnar Lund
Journal:  Eur Radiol       Date:  2017-06-14       Impact factor: 5.315

3.  A framework for accurate determination of the T₂ distribution from multiple echo magnitude MRI images.

Authors:  Ruiliang Bai; Cheng Guan Koay; Elizabeth Hutchinson; Peter J Basser
Journal:  J Magn Reson       Date:  2014-05-04       Impact factor: 2.229

4.  A majorize-minimize framework for Rician and non-central chi MR images.

Authors:  Divya Varadarajan; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2015-04-28       Impact factor: 10.048

5.  MRI Dynamic Range: Theory and Measurement.

Authors:  R E Gabr; M Schar; A D Edelstein; P A Bottomley; W A Edelstein
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2008

6.  Assessment of different fitting methods for in-vivo bi-component T2* analysis of human patellar tendon in magnetic resonance imaging.

Authors:  Fang Liu; Richard Kijowski
Journal:  Muscles Ligaments Tendons J       Date:  2017-05-10

7.  T1 mapping using saturation recovery single-shot acquisition at 3-tesla magnetic resonance imaging in hypertrophic cardiomyopathy: comparison to late gadolinium enhancement.

Authors:  Ryo Ogawa; Tomoyuki Kido; Masashi Nakamura; Teruhito Kido; Akira Kurata; Teruyoshi Uetani; Akiyoshi Ogimoto; Masao Miyagawa; Teruhito Mochizuki
Journal:  Jpn J Radiol       Date:  2017-01-19       Impact factor: 2.374

8.  Free-breathing post-contrast three-dimensional T1 mapping: Volumetric assessment of myocardial T1 values.

Authors:  Sebastian Weingärtner; Mehmet Akçakaya; Sébastien Roujol; Tamer Basha; Christian Stehning; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02-05       Impact factor: 4.668

9.  Optimal decay rate constant estimates from phased array data utilizing joint Bayesian analysis.

Authors:  James D Quirk; Alexander L Sukstanskii; G Larry Bretthorst; Dmitriy A Yablonskiy
Journal:  J Magn Reson       Date:  2009-01-13       Impact factor: 2.229

10.  Calculating T2 in images from a phased array receiver.

Authors:  Peter A Hardy; Anders H Andersen
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.