Literature DB >> 10196792

Evaluation of restorative and implant alloys galvanically coupled to titanium.

R Venugopalan1, L C Lucas.   

Abstract

OBJECTIVES: As the success of implants leads to their increasing use in restorative dentistry, attention should be devoted to the galvanic combination of restorative materials with titanium. This paper used continuous corrosion potential monitoring in conjunction with zero-resistance ammetry to obtain galvanic corrosion properties of restorative and implant materials coupled with titanium (ASTM F67-Grade II).
METHODS: Direct coupling or galvanic experiments were conducted on eight restorative and implant materials coupled to titanium. Deaerated artificial saliva solution in a specifically designed corrosion cell simulated an oral crevice situation. Open circuit potentials (Eo.c.) of each material in the couple, coupled corrosion potentials (Ecouple corr), coupled corrosion current density (lcouple corr) and the resultant charge transfer were monitored. The results were analyzed using single factor ANOVA and Duncan's multiple range tests.
RESULTS: Noble restorative (Au-, Ag-, and Pd-based) alloys coupled to titanium were found to be least susceptible to galvanic corrosion. Co-Cr-Mo, Ni-Cr and Fe-based alloys coupled to tatanium were found to be moderately susceptible to galvanic corrosion due to mechanical-electrochemical interaction. Ni-Cr-Be alloy coupled to titanium was found to be highly susceptible to galvanic corrosion. The in vitro test results for the titanium/Disperalloy combination does not concur with the published clinical performance of this combination, and thus warrants further investigation. SIGNIFICANCE: From the data obtained in this study and current literature profiles, acceptable restorative couples were developed for use as clinical guidelines in restorative dentistry.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10196792     DOI: 10.1016/s0109-5641(98)00024-4

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  8 in total

Review 1.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

2.  Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity.

Authors:  Jung-Jin Lee; Kwang-Yeob Song; Seung-Geun Ahn; Jung-Yun Choi; Jae-Min Seo; Ju-Mi Park
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

3.  Electrochemical Behaviour and Galvanic Effects of Titanium Implants Coupled to Metallic Suprastructures in Artificial Saliva.

Authors:  Ana Mellado-Valero; Anna Igual Muñoz; Virginia Guiñón Pina; Ma Fernanda Sola-Ruiz
Journal:  Materials (Basel)       Date:  2018-01-22       Impact factor: 3.623

4.  Pseudarthrosis due to galvanic corrosion presenting as subarachnoid hemorrhage.

Authors:  Rosemary Noel Beavers; Rishi Rajiv Lall; Juan Ortega Barnett; Sohum Kiran Desai
Journal:  J Craniovertebr Junction Spine       Date:  2017 Apr-Jun

5.  Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

Authors:  Susanne Merk; Christina Wagner; Veronika Stock; Marlis Eichberger; Patrick R Schmidlin; Malgorzata Roos; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-11-08       Impact factor: 3.623

6.  Electrical Potentiometry with Intraoral Applications.

Authors:  Alfonso Jornet-García; Arturo Sanchez-Perez; José María Montoya-Carralero; María José Moya-Villaescusa
Journal:  Materials (Basel)       Date:  2022-07-22       Impact factor: 3.748

Review 7.  Electrogalvanism in Oral Implantology: A Systematic Review.

Authors:  Meriem Amine; Wiam Merdma; Khalid El Boussiri
Journal:  Int J Dent       Date:  2022-08-05

8.  Results of titanium locking plate and stainless steel cerclage wire combination in femoral fractures.

Authors:  Bilal Farouk El-Zayat; Steffen Ruchholtz; Turgay Efe; Jürgen Paletta; Dimitri Kreslo; Ralph Zettl
Journal:  Indian J Orthop       Date:  2013-09       Impact factor: 1.251

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.