Literature DB >> 10196020

Use of contrast-enhanced computed tomography to measure clearance per unit renal volume: a novel measurement of renal function and fractional vascular volume.

Y Tsushima1, M J Blomley, S Kusano, K Endo.   

Abstract

The iodinated contrast agents used for computed tomography (CT) have pharmacokinetics similar to inulin and can measure physiological indices, such as clearance per unit renal volume (alpha/V) and fractional vascular volume (fvv). Clinical experience with these techniques is, however, scanty, and the present study explored their potential in subjects with and without renal dysfunction. In a series of subjects, a single slice of kidney was scanned sequentially after the bolus injection of contrast material. Time-attenuation curves were constructed, and alpha/V and fvv were calculated using a Patlak graphic analysis. In the first part of the study, 50 normal kidneys in 35 subjects (aged 21 to 75 years) were studied. In the second stage, alpha/V was compared with glomerular filtration rate (GFR) measurements in 24 patients with diabetes (aged 28 to 84 years) with or without renal dysfunction. In normal kidneys, alpha/V averaged 0.49 +/- 0.11 mL/min/mL and fvv averaged 35% +/- 12%. These values agree with literature data obtained using other techniques. A negative correlation was seen between age and alpha/V (r = 0.66; P < 0.0001), but not fvv. In patients with diabetes, a strong correlation was observed between renal clearance values, calculated from CT and corrected for renal volume, and GFR (r = 0.87; P < 0.0001). Dynamic CT can provide quantitative renal physiological information on a regional basis noninvasively.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10196020     DOI: 10.1016/s0272-6386(99)70230-1

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  7 in total

1.  A simple method to estimate renal volume from computed tomography.

Authors:  Rodney H Breau; Edward Clark; Bryan Bruner; Patrick Cervini; Thomas Atwell; Greg Knoll; Bradley C Leibovich
Journal:  Can Urol Assoc J       Date:  2013 May-Jun       Impact factor: 1.862

2.  Photoacoustic Imaging of Nanoparticle Transport in the Kidneys at High Temporal Resolution.

Authors:  Xingya Jiang; Bujie Du; Shaoheng Tang; Jer-Tsong Hsieh; Jie Zheng
Journal:  Angew Chem Int Ed Engl       Date:  2019-03-27       Impact factor: 15.336

3.  Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values.

Authors:  Paul S Tofts; Marica Cutajar; Iosif A Mendichovszky; A Michael Peters; Isky Gordon
Journal:  Eur Radiol       Date:  2012-03-14       Impact factor: 5.315

4.  Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs.

Authors:  Jinhwa Chang; Sujin Kim; Joohyun Jung; Heechun Lee; Hojung Choi; Dongwoo Chang; Youngwon Lee; Junghee Yoon; Mincheol Choi
Journal:  J Vet Sci       Date:  2011-12       Impact factor: 1.672

5.  Determination of split renal function using dynamic CT-angiography: preliminary results.

Authors:  Andreas Helck; Ulf Schönermarck; Antje Habicht; Mike Notohamiprodjo; Manfred Stangl; Ernst Klotz; Konstantin Nikolaou; Christian la Fougère; Dirk Andrè Clevert; Maximilian Reiser; Christoph Becker
Journal:  PLoS One       Date:  2014-03-11       Impact factor: 3.240

6.  Quantitative estimation of renal function with dynamic contrast-enhanced MRI using a modified two-compartment model.

Authors:  Bin Chen; Yudong Zhang; Xiaojian Song; Xiaoying Wang; Jue Zhang; Jing Fang
Journal:  PLoS One       Date:  2014-08-20       Impact factor: 3.240

7.  Noninvasive monitoring of chronic kidney disease using pH and perfusion imaging.

Authors:  KowsalyaDevi Pavuluri; Irini Manoli; Alexandra Pass; Yuguo Li; Hilary J Vernon; Charles P Venditti; Michael T McMahon
Journal:  Sci Adv       Date:  2019-08-14       Impact factor: 14.136

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.