Literature DB >> 10194726

A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction.

I Naert1, S Gizani, M Vuylsteke, D Van Steenberghe.   

Abstract

Prosthetic outcome and patient satisfaction were evaluated in order to investigate whether there is a need or advantage to splint two implants in the mandible retaining a hinging overdenture. This study included 36 fully edentulous patients randomly divided into three groups according to the attachment system they received: magnets, ball attachments or straight bars (reference group). None of the implants failed during the whole observation period in any of the groups. After 5 years of observation, the Bar group presented the highest retention capacity and the least prosthetic complications but revealed more mucositis and gingival hyperplasia. Patient satisfaction rated similar for all groups although the Magnet group showed lower retention forces. All patients would repeat the same treatment even though the majority of the Magnet group would prefer a more retentive solution because of limited denture stability.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10194726     DOI: 10.1046/j.1365-2842.1999.00369.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  18 in total

1.  Clinical retention force development of double crowns.

Authors:  Stefan Bayer; Helmut Stark; Lina Gölz; Ludger Keilig; Dominik Kraus; Anja Hansen; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2011-03-01       Impact factor: 3.573

2.  A comparative study on 7-year results of "All-on-Four™" immediate-function concept for completely edentulous mandibles: metal-ceramic vs. bar-retained superstructures.

Authors:  Mustafa Ayna; Aydin Gülses; Yahya Acil
Journal:  Odontology       Date:  2017-03-20       Impact factor: 2.634

3.  Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading.

Authors:  Sara Tavakolizadeh; Fariborz Vafaee; Masume Khoshhal; Zahra Ebrahimzadeh
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

4.  Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.

Authors:  Gunda Bernhart; Andreas Koob; Marc Schmitter; Olaf Gabbert; Thomas Stober; Peter Rammelsberg
Journal:  Clin Oral Investig       Date:  2011-07-26       Impact factor: 3.573

5.  Attachment systems for mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Jeong-Yol Lee; Sang-Wan Shin; S Ross Bryant
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

6.  Neurosensory disturbances after immediate loading of implants in the anterior mandible: an initial questionnaire approach followed by a psychophysical assessment.

Authors:  M Abarca; D van Steenberghe; C Malevez; J De Ridder; R Jacobs
Journal:  Clin Oral Investig       Date:  2006-08-26       Impact factor: 3.573

7.  Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures.

Authors:  Nobuhiro Yoda; Yoshiki Matsudate; Masaru Abue; Guang Hong; Keiichi Sasaki
Journal:  J Dent Biomech       Date:  2015-03-16

8.  Evaluation of subjective satisfaction of dental implant patients.

Authors:  Young-Kyun Kim; Hyun-Suk Kim; Yang-Jin Yi; Pil-Young Yun
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2014-06-27

9.  Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Sang-Wan Shin; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

10.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.