Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography.

A M Taylor1, P Jhooti, D N Firmin, D J Pennell.   

Abstract

Real-time navigator echo (NE)-gated magnetic resonance coronary angiography (MRCA) during free respiration is now possible. However, the mean diaphragm end-expiratory position (DEEP) drifts over time, and this results in a reduction in scanning efficiency and increased artifacts due to the acquisition of data during periods of high diaphragm velocity. To address these problems, a diaphragm monitoring program that follows the mean DEEP over time has been developed. Fifteen subjects with ischemic heart disease underwent continuous NE monitoring of their diaphragm for 30 minutes. Using these diaphragm traces, theoretical MRCA scans were performed. Several diaphragm monitoring algorithms were developed and compared with the simplest case (a stationary 5 mm NE acceptance window placed around the mean DEEP, as measured by NE monitoring at the outset of the scan). An overall scan efficiency was calculated, and the number of completed scans where the mean DEEP lay within the NE acceptance window was recorded. Of the six algorithms considered, the most effective one monitored the mean DEEP and prospectively placed the upper limit of the NE acceptance window on this position for the subsequent acquisition. Using this algorithm in comparison with the simplest stationary scenario, both scan efficiency (47.9% vs. 38.5%, P = 0.01) and the number of completed scans where the mean DEEP lay within the NE acceptance window (71.2 vs. 30.3, P < 0.001) were improved. The implementation of such a monitoring algorithm, in combination with adaptive motion correction techniques, should improve overall scan efficiency while maintaining the end-expiratory position at the top end of the NE acceptance window, to reduce image artifacts.

Entities:  

Mesh:

Year:  1999        PMID: 10194709     DOI: 10.1002/(sici)1522-2586(199903)9:3<395::aid-jmri6>3.0.co;2-y

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  9 in total

Review 1.  MR imaging of the coronary vasculature: imaging the lumen, wall, and beyond.

Authors:  Kai Lin; James C Carr
Journal:  Radiol Clin North Am       Date:  2015-03       Impact factor: 2.303

2.  3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography.

Authors:  M Hackenbroch; K Nehrke; J Gieseke; C Meyer; K Tiemann; H Litt; O Dewald; C P Naehle; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2005-04-07       Impact factor: 5.315

3.  Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T2 -prep for free-breathing, whole-heart coronary MRA.

Authors:  Andrew J Coristine; Jerome Chaptinel; Giulia Ginami; Gabriele Bonanno; Simone Coppo; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  Magn Reson Med       Date:  2017-05-31       Impact factor: 4.668

4.  Effects of respiratory motion on coronary wall MR imaging: a quantitative study of older adults.

Authors:  Kai Lin; Donald M Lloyd-Jones; Xiaoming Bi; Ying Liu; Debiao Li; James C Carr
Journal:  Int J Cardiovasc Imaging       Date:  2013-02-03       Impact factor: 2.357

5.  Reduction of flow- and eddy-currents-induced image artifacts in coronary magnetic resonance angiography using a linear centric-encoding SSFP sequence.

Authors:  Xiaoming Bi; Jaeseok Park; Vibhas Deshpande; Orlando Simonetti; Gerhard Laub; Debiao Li
Journal:  Magn Reson Imaging       Date:  2007-02-20       Impact factor: 2.546

6.  Free-breathing 3-dimensional steady-state free precession coronary magnetic resonance angiography: comparison of four navigator gating techniques.

Authors:  Thanh D Nguyen; Pascal Spincemaille; Matthew D Cham; Jonathan W Weinsaft; Martin R Prince; Yi Wang
Journal:  Magn Reson Imaging       Date:  2009-01-17       Impact factor: 2.546

7.  Beat-to-beat respiratory motion correction with near 100% efficiency: a quantitative assessment using high-resolution coronary artery imaging.

Authors:  Andrew D Scott; Jennifer Keegan; David N Firmin
Journal:  Magn Reson Imaging       Date:  2011-02-02       Impact factor: 2.546

8.  Impact of an abdominal belt on breathing patterns and scan efficiency in whole-heart coronary magnetic resonance angiography: comparison between the UK and Japan.

Authors:  Masaki Ishida; Andreas Schuster; Shinichi Takase; Geraint Morton; Amedeo Chiribiri; Boris Bigalke; Tobias Schaeffter; Hajime Sakuma; Eike Nagel
Journal:  J Cardiovasc Magn Reson       Date:  2011-11-17       Impact factor: 5.364

9.  Radial self-navigated native magnetic resonance angiography in comparison to navigator-gated contrast-enhanced MRA of the entire thoracic aorta in an aortic patient collective.

Authors:  Martina Correa Londono; Nino Trussardi; Verena C Obmann; Davide Piccini; Michael Ith; Hendrik von Tengg-Kobligk; Bernd Jung
Journal:  J Cardiovasc Magn Reson       Date:  2021-07-12       Impact factor: 5.364