Technical evaluation of five glucose meters with data management capabilities.

J J Chance1, D J Li, K A Jones, K L Dyer, J H Nichols.   

Abstract

Technical performance and data management features are prominent criteria in the selection of an appropriate meter for a point-of-care glucose testing program. We evaluated the technical performance of 5 currently available glucose meters with data management capabilities. The performance of all 5 meters was technically equivalent. Linear regression slopes vs the reference method are in the range of 0.94 to 1.02 and indicate correlation more to plasma values than to whole blood values. The percentage of glucose meter results within +/- 15% of the laboratory value was at least 90%; however, the percentage within +/- 10% was 75% to 87% for most meters. Within-day and between-day precision ranged from 2% to 5% coefficient of variation. Evaluation of linearity with glucose-spiked venous specimens demonstrated that the linearity of each meter agreed with the manufacturer's stated range in most cases. Meter glucose values tended to bias negative as the hematocrit increased, an effect that may be more pronounced at higher glucose concentrations. No volume effects were noted between 5 microL and 40 microL. The results suggest that all meters tested will likely satisfy technical performance criteria in a hospital setting and that selection of a system for point-of-care glucose testing will be influenced by the institution's data management requirements.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10191777     DOI: 10.1093/ajcp/111.4.547

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Impact of Glucose Meter Error on Glycemic Variability and Time in Target Range During Glycemic Control After Cardiovascular Surgery.

Authors:  Brad S Karon; Jeffrey W Meeusen; Sandra C Bryant
Journal:  J Diabetes Sci Technol       Date:  2015-08-25

2.  Comparative Accuracy Evaluation of a Blood Glucose Meter With Novel Hematocrit Correction Technology, With Three Currently Used Commercially Available Blood Glucose Monitoring Systems.

Authors:  Gareth J Dunseath; Dominic Bright; Stephen D Luzio
Journal:  J Diabetes Sci Technol       Date:  2019-01-09

3.  Factors interfering with the accuracy of five blood glucose meters used in Chinese hospitals.

Authors:  Hong Lv; Guo-jun Zhang; Xi-xiong Kang; Hui Yuan; Yan-wei Lv; Wen-wen Wang; Rollins Randall
Journal:  J Clin Lab Anal       Date:  2013-09       Impact factor: 2.352

4.  Recommendation on Reporting Results for Blood Glucose (From an IFCC Stage 1 Document) IFCC Scientific Division Working Group on Selective Electrodes.

Authors:  Niels Fogh-Andersen; Paul D'Orazio; Katsuhiko Kuwa; Wolf R Külpmann; Gerhard Mager; Lasse Larsson
Journal:  EJIFCC       Date:  2000-12-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.