Literature DB >> 10190358

Acute thermal injury to the canine jejunal free flap: electrocautery versus ultrasonic dissection.

D W Birch1, A Park, H Shuhaibar.   

Abstract

Electrocautery-induced thermal injury contributes to morbidity and mortality after laparoscopic surgery. Ultrasonic dissection is an alternative technique that may produce less thermal injury. We compared the amount of acute thermal injury caused to jejunal free flaps isolated with laparoscopic electrosurgical instruments with that caused by ultrasonic dissection (laparoscopic coagulating shears). Canine jejunal free flaps were isolated by electrocautery or laparosonic coagulating shears and remained viable on a vascular pedicle. After a period of ischemia and reperfusion, the flaps were resected to simulate harvesting and reimplantation. Thermal injury was observed at the site of dissection and was graded histologically. At the margin of the jejunal free flaps, the laparosonic coagulating shears produced less thermal injury (score, 2.2 at level 3) than the electrocautery grasping forceps (score, 3.7 at 35 W and 4.1 at 70 W). The laparosconic coagulating shears produced less thermal injury to a jejunal free flap than did electrocautery. Ultrasonic dissection is an alternative to the complications produced by electrocautery during laparoscopic dissection.

Entities:  

Mesh:

Year:  1999        PMID: 10190358

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  6 in total

1.  Comparison of monopolar electrocoagulation, bipolar electrocoagulation, Ultracision, and Ligasure.

Authors:  Theodore Diamantis; Michael Kontos; Antonios Arvelakis; Spiridon Syroukis; Dimitris Koronarchis; Apostolos Papalois; Emmanuel Agapitos; Elias Bastounis; Andreas C Lazaris
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

2.  Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT).

Authors:  F J Kim; M F Chammas; E Gewehr; M Morihisa; F Caldas; E Hayacibara; M Baptistussi; F Meyer; A C Martins
Journal:  Surg Endosc       Date:  2007-11-20       Impact factor: 4.584

3.  Evaluation of mist production and tissue dissection efficiency using different types of ultrasound shears.

Authors:  A Schneider; E Doundoulakis; S Can; A Fiolka; D Wilhelm; H Feussner
Journal:  Surg Endosc       Date:  2009-05-23       Impact factor: 4.584

4.  Repeated partial tissue bite with inadequate cooling time for an energy device may cause thermal injury.

Authors:  Kazunori Shibao; Fumi Joden; Yasuhiro Adachi; Shiro Kohi; Yuzan Kudou; Yuta Kikuchi; Nobutaka Matayoshi; Nagahiro Sato; Ryota Murayama; Keiji Hirata
Journal:  Surg Endosc       Date:  2021-02-01       Impact factor: 4.584

5.  Randomized clinical trial of torsional versus linear mode ultrasonically activated devices for laparoscopic cholecystectomy.

Authors:  Siok S Ching; Abeezar I Sarela; Jeremy D Hayden; Michael J McMahon
Journal:  Surg Endosc       Date:  2009-03-05       Impact factor: 4.584

6.  Thyroid surgery with a harmonic scalpel: an experimental study.

Authors:  Didier Dequanter; Martin Lammens; Nathalie Nagy; Mohammad Shahla; Yasmine Deniz; Christine Aubert; Youri Vanhemelrijck; Philippe Lothaire
Journal:  Med Devices (Auckl)       Date:  2016-06-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.