The role of inertial particle collectors in evaluating pharmaceutical aerosol delivery systems.

V A Marple1, B A Olson, N C Miller.   

Abstract

Design theory for cascade impactors is well developed, and design principles can be summarized quite succinctly. The key geometric parameters of three commonly used impactors have been compared to design guidelines. Calibration theory and practice have undergone improvement in recent years. Published results show distinctly different characteristics for three commonly used impactors, and conformance to modern design recommendations results in desirable performance characteristics. A consideration of the sensitivity of stage collection efficiency characteristics to geometric variables and flow rate indicates that measurement of certain physical dimensions is sufficient to assure that impactor performance matches that of a properly calibrated unit. Flow rate is an important operating variable that is more likely to fall out of its calibrated range than important dimensional variables resulting from instrument manufacturing. In practice, data from impactors are frequently treated as though the impactors have ideal collection characteristics. The practical effects of impactor nonideal performance can be demonstrated by model calculations, and these show the necessity of data inversion to obtain a size distribution. The process is not straightforward for unknown distributions. There are much smaller differences between ideal and real performance for an impactor complying with design guidelines, thus, the cutoff characteristics are sharp.

Mesh:

Substances:

Year:  1998        PMID: 10180727

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  8 in total

1.  Relative precision of inhaler aerodynamic particle size distribution (APSD) metrics by full resolution and abbreviated andersen cascade impactors (ACIs): part 1.

Authors:  Jolyon P Mitchell; Mark W Nagel; Cathy C Doyle; Rubina S Ali; Valentina I Avvakoumova; J David Christopher; Jorge Quiroz; Helen Strickland; Terrence Tougas; Svetlana Lyapustina
Journal:  AAPS PharmSciTech       Date:  2010-05-18       Impact factor: 3.246

2.  Relative precision of inhaler aerodynamic particle size distribution (APSD) metrics by full resolution and abbreviated andersen cascade impactors (ACIs): part 2--investigation of bias in extra-fine mass fraction with AIM-HRT impactor.

Authors:  Jolyon P Mitchell; Mark W Nagel; Cathy C Doyle; Rubina S Ali; Valentina I Avvakoumova; J David Christopher; Jorge Quiroz; Helen Strickland; Terrence Tougas; Svetlana Lyapustina
Journal:  AAPS PharmSciTech       Date:  2010-07-10       Impact factor: 3.246

Review 3.  In vitro and in vivo aspects of cascade impactor tests and inhaler performance: a review.

Authors:  Jolyon Mitchell; Steve Newman; Hak-Kim Chan
Journal:  AAPS PharmSciTech       Date:  2007-12-21       Impact factor: 3.246

4.  The abbreviated impactor measurement (AIM) concept: part 1--Influence of particle bounce and re-entrainment-evaluation with a "dry" pressurized metered dose inhaler (pMDI)-based formulation.

Authors:  J P Mitchell; M W Nagel; V Avvakoumova; H MacKay; R Ali
Journal:  AAPS PharmSciTech       Date:  2009-03-12       Impact factor: 3.246

5.  Effects of Temperature and Humidity on Laser Diffraction Measurements to Jet Nebulizer and Comparison with NGI.

Authors:  Xinghan Song; Junhua Hu; Shuyao Zhan; Rui Zhang; Wen Tan
Journal:  AAPS PharmSciTech       Date:  2015-07-14       Impact factor: 3.246

Review 6.  Mechanisms of pharmaceutical aerosol deposition in the respiratory tract.

Authors:  Yung Sung Cheng
Journal:  AAPS PharmSciTech       Date:  2014-02-22       Impact factor: 3.246

7.  Accessorized DPI: a Shortcut towards Flexibility and Patient Adaptability in Dry Powder Inhalation.

Authors:  Francesca Buttini; James Hannon; Kristi Saavedra; Irene Rossi; Anna Giulia Balducci; Hugh Smyth; Andy Clark; Paolo Colombo
Journal:  Pharm Res       Date:  2016-09-13       Impact factor: 4.200

8.  Aerodynamic particle size analysis of aerosols from pressurized metered-dose inhalers: comparison of Andersen 8-stage cascade impactor, next generation pharmaceutical impactor, and model 3321 Aerodynamic Particle Sizer aerosol spectrometer.

Authors:  Jolyon P Mitchell; Mark W Nagel; Kimberly J Wiersema; Cathy C Doyle
Journal:  AAPS PharmSciTech       Date:  2003-10-22       Impact factor: 3.246

  8 in total