Literature DB >> 10150994

Histologic identification of polyethylene wear debris using Oil Red O stain.

T P Schmalzried1, M Jasty, A Rosenberg, W H Harris.   

Abstract

Ultra high molecular weight polyethylene (UHMWPE) wear particles are frequently implicated in causing failure of total joint arthroplasties by eliciting a foreign body reaction. The majority of these particles are subcellular and many are submicron in size. Identification of these small particles of UHMWPE by conventional histologic techniques is difficult. We have therefore investigated the utility of Oil Red O (ORO) stain to identify UHMWPE on histologic sections. A wide variety of specimens was studied including an experimental rabbit model with subcutaneous implantation of polyethylene particles as well as specimens from clinical cases with joint arthroplasties. The sensitivity and specificity of ORO stain was compared to conventional polarized light microscopy for the identification of particulate UHMWPE debris. The ORO stain was found to be as sensitive in identifying particulate UHMWPE debris as polarized light microscopy. However, ORO stain was less specific: two specimens did not contain any UHMWPE also stained with ORO. Careful examination of standard hematoxylin and eosin stained sections with polarized light was therefore more specific for the identification of particulate UHMWPE. As a single test, the ORO stain does not appear to offer any clear advantage specifically for the identification of UHMWPE.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 10150994     DOI: 10.1002/jab.770040202

Source DB:  PubMed          Journal:  J Appl Biomater        ISSN: 1045-4861


  3 in total

1.  [Proposal for the classification of the periprosthetic membrane from loosened hip and knee endoprostheses].

Authors:  L Morawietz; Th Gehrke; R-A Classen; B Barden; M Otto; T Hansen; Th Aigner; P Stiehl; J Neidel; J H Schröder; L Frommelt; Th Schubert; C Meyer-Scholten; A König; Ph Ströbel; Ch P Rader; S Kirschner; F Lintner; W Rüther; A Skwara; I Bos; J Kriegsmann; V Krenn
Journal:  Pathologe       Date:  2004-09       Impact factor: 1.011

2.  Proposal for a histopathological consensus classification of the periprosthetic interface membrane.

Authors:  L Morawietz; R-A Classen; J H Schröder; C Dynybil; C Perka; A Skwara; J Neidel; T Gehrke; L Frommelt; T Hansen; M Otto; B Barden; T Aigner; P Stiehl; T Schubert; C Meyer-Scholten; A König; P Ströbel; C P Rader; S Kirschner; F Lintner; W Rüther; I Bos; C Hendrich; J Kriegsmann; V Krenn
Journal:  J Clin Pathol       Date:  2006-06       Impact factor: 3.411

3.  An evaluation of the host response to an interspinous process device based on a series of spine explants: Device for Intervertebral Assisted Motion (DIAM®).

Authors:  Jeffrey M Toth; Justin D Bric
Journal:  J Spine Surg       Date:  2019-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.