Literature DB >> 10147922

Pupil perimetry.

R H Kardon.   

Abstract

The pupillomotor and visual sensitivity were compared at the same 76 points across the 30 degrees field. The timing and amplitude of pupillary contractions to focal light stimuli were recorded using a computerized infrared pupillometer linked to a Humphrey automated perimeter. Pupil perimetry and standard threshold perimetry showed matching defects in the visual field of patients with ischemic and compressive optic neuropathy, but not in patients with primary open-angle glaucoma. Patients with isolated occipital strokes showed matching homonymous visual and pupillary fields, suggesting a suprageniculate influence upon the pupillary light reflex. Pupil perimetry is a useful objective form of perimetry and can be used to compare the effect of disease on the visual and pupillary pathways.

Entities:  

Mesh:

Year:  1992        PMID: 10147922     DOI: 10.1097/00055735-199210000-00002

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  13 in total

1.  [Current state of pupil-based diagnostics for glaucomatous optic neuropathy].

Authors:  K Skorkovská; U Schiefer; B Wilhelm; H Wilhelm
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

2.  Pupillary evaluation of retinal asymmetry: development and initial testing of a technique.

Authors:  Yanjun Chen; Harry J Wyatt; William H Swanson
Journal:  Vision Res       Date:  2005-09       Impact factor: 1.886

3.  What rates of glaucoma progression are clinically significant?

Authors:  Luke J Saunders; Felipe A Medeiros; Robert N Weinreb; Linda M Zangwill
Journal:  Expert Rev Ophthalmol       Date:  2016-05-13

4.  Chromatic pupillography in hemianopia patients with homonymous visual field defects.

Authors:  Fumiatsu Maeda; Carina Kelbsch; Torsten Straßer; Karolína Skorkovská; Tobias Peters; Barbara Wilhelm; Helmut Wilhelm
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-06-30       Impact factor: 3.117

5.  How sensitive is pupil campimetry in hemifield loss?

Authors:  Karolína Skorkovská; Helmut Wilhelm; Holger Lüdtke; Barbara Wilhelm
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-02-19       Impact factor: 3.117

6.  Studying the effect of iris mechanics on the pupillary light reflex using brimonidine-induced anisocoria.

Authors:  Yanjun Chen; Randy H Kardon
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-04-26       Impact factor: 4.799

7.  In vivo functional imaging of intrinsic scattering changes in the human retina with high-speed ultrahigh resolution OCT.

Authors:  V J Srinivasan; Y Chen; J S Duker; J G Fujimoto
Journal:  Opt Express       Date:  2009-03-02       Impact factor: 3.894

8.  A novel Bayesian adaptive method for mapping the visual field.

Authors:  Pengjing Xu; Luis Andres Lesmes; Deyue Yu; Zhong-Lin Lu
Journal:  J Vis       Date:  2019-12-02       Impact factor: 2.240

9.  Relative Afferent Pupillary Defects in Homonymous Visual Field Defects Caused by Stroke of the Occipital Lobe Using Pupillometer.

Authors:  Go Takizawa; Atsushi Miki; Fumiatsu Maeda; Katsutoshi Goto; Syunsuke Araki; Tsutomu Yamashita; Yoshiaki Ieki; Junichi Kiryu; Kiyoshi Yaoeda
Journal:  Neuroophthalmology       Date:  2017-08-31

10.  Gaze-Contingent Flicker Pupil Perimetry Detects Scotomas in Patients With Cerebral Visual Impairments or Glaucoma.

Authors:  Marnix Naber; Carlien Roelofzen; Alessio Fracasso; Douwe P Bergsma; Mies van Genderen; Giorgio L Porro; Serge O Dumoulin
Journal:  Front Neurol       Date:  2018-07-10       Impact factor: 4.003

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.