Three-dimensional and four-dimensional transesophageal echocardiographic imaging of the heart and aorta in humans using a computed tomographic imaging probe.

N G Pandian1, N C Nanda, S L Schwartz, P Fan, Q L Cao, R Sanyal, T L Hsu, B Mumm, H Wollschläger, A Weintraub.   

Abstract

We evaluated the clinical applicability of a prototype tomographic transesophageal echocardiographic (TEE) system, which not only provides conventional TEE images but also three-dimensional tissue reconstruction and four-dimensional display capabilities. The probe was used in 16 patients in the echocardiographic laboratory, intensive care unit, and the operating room. The instrument is a 5-MHz, 64-element, phased array unit mounted on a sliding carriage within a casing. After appropriate probe placement within the esophagus, the probe is straightened, a balloon surrounding the probe is inflated, and data acquisition begun with ECG and respiration gating. With computer controlled transducer movement at 1-mm increments, a complete cardiac cycle is recorded at each tomographic level. These are processed using a dedicated four-dimensional software, and displayed as a dynamic three-dimensional tissue image of the heart. We were able to see the dynamic motion of the ventricles and all the valves in the four-dimensional format. In addition to four-dimensional display, we were able to cut and visualize the heart in dynamic mode in any desired plane and also in multiple planes. Patients tolerated the procedure well. We conclude that this tomographic four-dimensional approach, which does not require tedious off-line processing, can easily be performed in patients and has a strong clinical potential.

Entities:  

Mesh:

Year:  1992        PMID: 10147804     DOI: 10.1111/j.1540-8175.1992.tb00513.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  12 in total

1.  Evaluation of mitral valve prolapse using newly developed real-time three-dimensional echocardiographic system with real-time volume rendering.

Authors:  Omer Goktekin; Makoto Matsumura; Ryozo Omoto; Shunei Kyo; Tsuyoshi Mochizuki
Journal:  Int J Cardiovasc Imaging       Date:  2003-02       Impact factor: 2.357

2.  A method for the morphological analysis of the regurgitant mitral valve using three dimensional echocardiography.

Authors:  A Macnab; N P Jenkins; I Ewington; B J M Bridgewater; T L Hooper; D L Greenhalgh; M R Patrick; S G Ray
Journal:  Heart       Date:  2004-07       Impact factor: 5.994

3.  Three dimensional reconstruction of the heart with rotational acquisition: methods and clinical applications.

Authors:  A Salustri; J Roelandt
Journal:  Br Heart J       Date:  1995-05

4.  Study on three dimensional reconstruction of transesophageal echocardiographic images.

Authors:  Z A Li; X F Wang; P Lu; G Hu; L H Zheng; Y Yang
Journal:  J Tongji Med Univ       Date:  1995

Review 5.  Evolving trends and future directions in echocardiography.

Authors:  N G Pandian; M A Vannan
Journal:  Int J Card Imaging       Date:  1993

6.  Assessment of atrial septal defect morphology by transthoracic three dimensional echocardiography using standard grey scale and Doppler myocardial imaging techniques: comparison with magnetic resonance imaging and intraoperative findings.

Authors:  A Lange; M Walayat; C M Turnbull; P Palka; P Mankad; G R Sutherland; M J Godman
Journal:  Heart       Date:  1997-10       Impact factor: 5.994

7.  [Improved structure identification with tissue Doppler echocardiography].

Authors:  T Bartel; S Müller; S Möhlenkamp; C Bruch; J Schaar; R Erbel
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

8.  Preoperative assessment of cor triatriatum in an adult by dynamic three dimensional echocardiography was more informative than transoesophageal echocardiography or magnetic resonance imaging.

Authors:  T Bartel; S Müller; A Geibel
Journal:  Br Heart J       Date:  1994-11

9.  Dynamic three-dimensional transesophageal echocardiography using a computed tomographic imaging probe--clinical potential and limitation.

Authors:  A C Borges; T Bartel; S Müller; G Baumann
Journal:  Int J Card Imaging       Date:  1995-12

10.  Dynamic three-dimensional echocardiography with a computed tomography imaging probe: initial clinical experience with transthoracic application in infants and children with congenital heart defects.

Authors:  M Vogel; S Lösch
Journal:  Br Heart J       Date:  1994-05