Literature DB >> 10147254

Continuous invasive cardiac output monitoring--the Baxter/Edwards Critical-Care Swan Ganz IntelliCath and Viligance system.

H M Munro1, C E Wood, B L Taylor, G B Smith.   

Abstract

We evaluated the Baxter/Edwards Critical-Care Swan Ganz IntelliCath continuous cardiac output catheter and Vigilance continuous cardiac output monitor in critically ill adult intensive care patients, and compared cardiac output measurements obtained from this new system with those from a standard bolus thermodilution technique using cold normal saline. Nine Swan Ganz IntelliCath catheters were inserted into patients selected at random, following the decision that pulmonary artery catheter monitoring was required. A total of 100 comparisons were made in nine patients. We found the Swan Ganz IntelliCath catheter to be both easy to insert and position, and simple to use. There were no complications or technical difficulties. The mean cardiac output measured by the continuous system was 8.00 l/min (SD 1.66/min) compared to 8.02 1/min (SD 1.74 l/min) using bolus techniques. Continuous cardiac output values correlated well with bolus measurements (r = 0.87), there was excellent accuracy (bias of 0.02 l/min) and precision was acceptable (limits of agreement of -1.71 to 1.75 l/min). These larger than anticipated limits of agreement may not reflect any inaccuracy in the continuous measurement system, rather they may highlight the extent of well recognised potential errors inherent in the intermittent bolus technique. The availability of a system to measure cardiac output continuously provides a major improvement in intensive care monitoring. This system will permit the rapid and accurate assessment of the response of patients to therapy while providing increased diagnostic facilities and a new research tool.

Entities:  

Mesh:

Year:  1994        PMID: 10147254

Source DB:  PubMed          Journal:  Clin Intensive Care        ISSN: 0956-3075


  8 in total

1.  Safety of the transpulmonary ultrasound contrast agent NC100100: a clinical and haemodynamic evaluation in patients with suspected or proved coronary artery disease.

Authors:  Y Myreng; P Molstad; K Ytre-Arne; M Aas; L Stoksflod; J O Nossen; B Oftedal
Journal:  Heart       Date:  1999-09       Impact factor: 5.994

2.  Reproducibility of thermodilution cardiac output determination in critically ill patients: comparison between bolus and continuous method.

Authors:  Y Le Tulzo; M Belghith; P Seguin; J Dall'Ava; M Monchi; R Thomas; J F Dhainaut
Journal:  J Clin Monit       Date:  1996-09

3.  Effects of sevoflurane and propofol on right ventricular function and pulmonary circulation in patients undergone esophagectomy.

Authors:  Wen-Yun Xu; Na Wang; Hai-Tao Xu; Hong-Bin Yuan; Hai-Jing Sun; Chun-Li Dun; Shuang-Qiong Zhou; Zui Zou; Xue-Yin Shi
Journal:  Int J Clin Exp Pathol       Date:  2013-12-15

4.  Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia.

Authors:  Jens D Hove; Klaus F Kofoed; Hsiao M Wu; Søren Holm; Lars Friberg; Christian Meyer; Jan Aldershvile; Birger Hesse; Henning Kelbaek
Journal:  J Nucl Cardiol       Date:  2003 Jan-Feb       Impact factor: 5.952

Review 5.  Haemodynamic monitoring in acute heart failure.

Authors:  Maurizio Cecconi; Toby E Reynolds; Nawaf Al-Subaie; Andrew Rhodes
Journal:  Heart Fail Rev       Date:  2007-06       Impact factor: 4.214

Review 6.  What role does the right side of the heart play in circulation?

Authors:  Maurizio Cecconi; Edward Johnston; Andrew Rhodes
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

7.  Inducing Brain Cooling Without Core Temperature Reduction in Pigs Using a Novel Nasopharyngeal Method: An Effectiveness and Safety Study.

Authors:  Bernardo Lembo Conde de Paiva; Edson Bor-Seng-Shu; Eliezer Silva; Ícaro Barros Miranda Barreto; Marcelo de Lima Oliveira; Raphael Einsfeld Simões Ferreira; Alexandre Biasi Cavalcanti; Manoel Jacobsen Teixeira
Journal:  Neurocrit Care       Date:  2020-04       Impact factor: 3.210

Review 8.  Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies--with specific reference to the measurement of cardiac output.

Authors:  Maurizio Cecconi; Andrew Rhodes; Jan Poloniecki; Giorgio Della Rocca; R Michael Grounds
Journal:  Crit Care       Date:  2009-01-13       Impact factor: 9.097

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.